2019
DOI: 10.1007/s41742-019-00236-2
|View full text |Cite
|
Sign up to set email alerts
|

Highly Selective and Sensitive Sensing of Toxic Mercury Ions Utilizing Carbon Quantum Dot-Modified Glassy Carbon Electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 39 publications
0
7
0
Order By: Relevance
“…Hyperconcentration of mercury affects the heart, kidney, nervous system, and liver. 4,5 Therefore, USA EPA has set the highest concentration limit of mercury in water as 2 ppb. Hence, the selective detection of mercury below the limits set by USA EPA is highly required.…”
Section: Introductionmentioning
confidence: 99%
“…Hyperconcentration of mercury affects the heart, kidney, nervous system, and liver. 4,5 Therefore, USA EPA has set the highest concentration limit of mercury in water as 2 ppb. Hence, the selective detection of mercury below the limits set by USA EPA is highly required.…”
Section: Introductionmentioning
confidence: 99%
“…The optical properties of CDs were also studied, the UV‐vis spectrum recorded in aqueous medium is shown in Figure 4a. It exhibited a band in the UV region at 278 nm, which is due to n‐ π ${\pi }$ * transition of C=O and conjugated C=C [35,36] . These CDs are highly fluorescent, its fluorescence spectrum recorded upon excitation at 340 nm is shown in Figure 4a, which exhibited a strong band at 425 nm.…”
Section: Resultsmentioning
confidence: 99%
“…It exhibited a band in the UV region at 278 nm, which is due to np* transition of C=O and conjugated C=C. [35,36] These CDs are highly fluorescent, its fluorescence spectrum recorded upon excitation at 340 nm is shown in Figure 4a, which exhibited a strong band at 425 nm. The similarity in the CDs prepared in each batch and its stability before using it for any study was checked with the aid of UV-Vis and fluorescence spectral studies conducted under same experimental conditions.…”
Section: Optical Property Of CDmentioning
confidence: 99%
“…It became an issue that how to distinguish between CU and MY (Shereema et al, 2018) Excessive Hg 2+ levels in food can cause harm to the human body. Barvin et al (2019) dropped CDs solution onto GCE to prepare electrodes for detecting Hg 2+ . The LOD for Hg 2+ is 2.5 nM (2.5-350 nM).…”
Section: Modified Electrodementioning
confidence: 99%