2001
DOI: 10.1016/s0003-2670(01)01051-0
|View full text |Cite
|
Sign up to set email alerts
|

Highly selective and sensitive copper(II) membrane coated graphite electrode based on a recently synthesized Schiff’s base

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0

Year Published

2003
2003
2013
2013

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 96 publications
(35 citation statements)
references
References 31 publications
0
35
0
Order By: Relevance
“…Table 1 Besides the critical role of the nature of the ion carrier in preparing membrane-selective sensors, some other important features of the PVC membrane, such as the amount of ionophore, the nature of solvent mediator, the plasticizer/PVC ratio, and, especially, the nature of the additives used, are known to significantly influence the sensitivity and selectivity of ion-selective electrodes. [9][10][11][12][13][14][15] As is obvious from Table 1 (No. 5,9 -11), among four different plasticizer used, DBP was a more effective solvent mediator in preparing the imidazole sensor.…”
Section: Resultsmentioning
confidence: 84%
See 2 more Smart Citations
“…Table 1 Besides the critical role of the nature of the ion carrier in preparing membrane-selective sensors, some other important features of the PVC membrane, such as the amount of ionophore, the nature of solvent mediator, the plasticizer/PVC ratio, and, especially, the nature of the additives used, are known to significantly influence the sensitivity and selectivity of ion-selective electrodes. [9][10][11][12][13][14][15] As is obvious from Table 1 (No. 5,9 -11), among four different plasticizer used, DBP was a more effective solvent mediator in preparing the imidazole sensor.…”
Section: Resultsmentioning
confidence: 84%
“…formed. [9][10][11][12][13][14][15] The tube was then pulled out from the mixture and kept at room temperature for 1 h. The tube was then filled with an internal solution (1.0 × 10 -3 imidazole). The electrode was finally conditioned for about 12 h by soaking in a 1.0 × 10 -2 M of imidazole solution.…”
Section: Electrode Preparationmentioning
confidence: 99%
See 1 more Smart Citation
“…Our recently reserches showed that, the Schiff , s base compounds can form a fairly stable and selective complex with transition and heavy metal ions, specially copper 23 . To the best of our knowledge, there is no report on the stability of SBTD complexes with metal ions.…”
Section: Resultsmentioning
confidence: 99%
“…[13][14][15][16][17][18][19][20][21] Thus, several membranes of various plasticizer/PVC/II/ additive ratios were tested and the results are summarized in Table 1.…”
Section: Jmentioning
confidence: 99%