2011
DOI: 10.1016/j.bios.2010.09.021
|View full text |Cite
|
Sign up to set email alerts
|

Highly reproducible immunoassay of cancer markers on a gold-patterned microarray chip using surface-enhanced Raman scattering imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
56
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 135 publications
(58 citation statements)
references
References 36 publications
0
56
0
Order By: Relevance
“…In order to improve the consistency of SERS measurements, recent focus has been placed on improving the chip-scale measurement uniformity either by implementing better substrates, [31][32][33][34] or employing better measurement strategies such as areal averaging, [35][36] which involves scanning a larger area on the substrate to collect and average more Raman-signal data points as opposed to 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 making a single point measurement. Two-dimensional (2D) mapping of Raman spectra was performed over a 1×1 mm 2 increasing the average scan area from 50×50 µm 2 to 400×400 µm 2 reduces the RSD from 3.6% to 1.7%.…”
mentioning
confidence: 99%
“…In order to improve the consistency of SERS measurements, recent focus has been placed on improving the chip-scale measurement uniformity either by implementing better substrates, [31][32][33][34] or employing better measurement strategies such as areal averaging, [35][36] which involves scanning a larger area on the substrate to collect and average more Raman-signal data points as opposed to 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 making a single point measurement. Two-dimensional (2D) mapping of Raman spectra was performed over a 1×1 mm 2 increasing the average scan area from 50×50 µm 2 to 400×400 µm 2 reduces the RSD from 3.6% to 1.7%.…”
mentioning
confidence: 99%
“…There are several reports regarding the use of the technique in immunoassays format for protein or microorganism detection [135][136][137][138][139][140][141]. In immunoassay-based approaches, a recognition element, an antibody, captures the target and a transducer converts the biological recognition to readout.…”
Section: Detection Identification and Characterization Of Biomacrommentioning
confidence: 99%
“…In another recent report, immunoassay-based SERS method for the detection of cancer marker, angiogenin (ANG), and alpha-fetoprotein (AFP), was successfully demonstrated with a detection limit of 0.1 pg/mL and 1.0 pg/mL, respectively [138]. Wang et al demonstrated the detection of MUC4 in real samples, which is a pancreatic cancer marker, using a SERS-based immunoassay platform [139].…”
Section: Detection Identification and Characterization Of Biomacrommentioning
confidence: 99%
“…Surface-enhanced Raman scattering (SERS) is an emerging technique that allows sensitive, selective, and rapid biomarker detection [1][2][3]. For this reason, there is increasing interest in using SERS-based techniques in clinical diagnostics.…”
Section: Introductionmentioning
confidence: 99%