IECON 2020 the 46th Annual Conference of the IEEE Industrial Electronics Society 2020
DOI: 10.1109/iecon43393.2020.9254657
|View full text |Cite
|
Sign up to set email alerts
|

Highly Flexible Indirect Modular Multilevel Converter for High Power Pumped Hydro Storage Plants

Abstract: As fossil-fuel-and nuclear-based generating facilities are being phased-out in favor of intermittent renewable energy sources, the need for large scale, highly flexible balancing storage is imminent. By the generating capacity of readily available units, enormous potential lays in retrofitting of large pumped hydro storage plants to variable speed operation, increasing their flexibility to meet future power system demands. Indirect Modular Multilevel Converter is a highly scalable and inherently redundant topo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 12 publications
(16 reference statements)
0
7
0
Order By: Relevance
“…CM voltage-free low frequency operation of a machine-side MMC is enabled through variable DC link voltage operation [34], [23]. In the VSD application, only positive DC voltage values are of interest, defined henceforth by the factor k DC ∈ (0, 1] such that V DC = k DC V DC,n , as briefly analyzed hereafter.…”
Section: Variable DC Link Voltage Operationmentioning
confidence: 99%
See 2 more Smart Citations
“…CM voltage-free low frequency operation of a machine-side MMC is enabled through variable DC link voltage operation [34], [23]. In the VSD application, only positive DC voltage values are of interest, defined henceforth by the factor k DC ∈ (0, 1] such that V DC = k DC V DC,n , as briefly analyzed hereafter.…”
Section: Variable DC Link Voltage Operationmentioning
confidence: 99%
“…CM-voltage-free operation can be performed by varying the DC link voltage with output machine frequency, in the range (0, V DC,n ], V DC,n denoting rated DC voltage value [22], [23]. However, HB-based MMC Active Front-End (AFE) operation is limited to a narrow band around V DC,n , owing to fixed grid-side AC voltage amplitude.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…10 can be defined. The main objective to reduce the number of state space matrices has successfully been achieved as with the splitting, this number was reduced to 3 × 2 6 .…”
Section: Splitting Of the M3c Modelmentioning
confidence: 99%
“…The high power requirements of PHSP constitute a challenge for Variable Speed Drive (VSD) due to the converter requirements, making conventional converters unsuited for such applications. However, the rise of the Modular Multilevel Converter (MMC) technology [5] allows, due to its modularity which relies on the series connection of cells, each with its own capacitor, to be scaled to the power and voltage requirements of PHSP [6], while current scaling can be achieved as explained in [7], [8]. Additionally the elimination of the connected transformer as well as the This paper was submitted on the 25 th of August 2021.…”
Section: Introductionmentioning
confidence: 99%