2012
DOI: 10.1016/j.intermet.2012.03.044
|View full text |Cite
|
Sign up to set email alerts
|

High-throughput study of martensitic transformations in the complete Ti–Ni–Cu system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
30
1
1

Year Published

2013
2013
2020
2020

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 39 publications
(35 citation statements)
references
References 74 publications
3
30
1
1
Order By: Relevance
“…The other splats show a much clearer non-linearity in the R(T) curve. In contrast to R(T) measurements of conventional shape memory alloys (SMAs) [15] and extremely rapidly quenched Fe 70 Pd 30 thin films using microhotplates [16], these samples show only weak changes in the R(T) curve with no determinable hysteresis width. Therefore it is not possible to distinguish between martensite start (M s ) and austenite finish (A f ) or martensite finish (M f ) and austenite start (A s ) temperature.…”
Section: Resultscontrasting
confidence: 62%
“…The other splats show a much clearer non-linearity in the R(T) curve. In contrast to R(T) measurements of conventional shape memory alloys (SMAs) [15] and extremely rapidly quenched Fe 70 Pd 30 thin films using microhotplates [16], these samples show only weak changes in the R(T) curve with no determinable hysteresis width. Therefore it is not possible to distinguish between martensite start (M s ) and austenite finish (A f ) or martensite finish (M f ) and austenite start (A s ) temperature.…”
Section: Resultscontrasting
confidence: 62%
“…Library synthesis and metrology tools are often expensive and not readily available commercially and therefore 133 not accessible to most materials researchers. Currently, HTE libraries and measurement tools are primarily designed with the goal of materials discovery and optimization; therefore, composition is the most common variable HTE parameter.…”
Section: High-throughput Synthesis and Characterization Of Materials mentioning
confidence: 99%
“…As part of the same study, it was shown that the "zero-hysteresis" compositions identified from the CCS experiments, when processed as bulk samples, indeed showed substantially enhanced functional stability due to minimized fatigue behavior. Zarnetta et al 419,420 have also investigated the details of phase transformation behavior across a variety of related SMA systems. Figure 81 shows one such study where data cluster analysis was performed on XRD spectra from a Ni-Ti-Cu CCS library.…”
Section: High-throughput Mapping Of Phase Diagramsmentioning
confidence: 99%