2020
DOI: 10.1002/bmc.4790
|View full text |Cite
|
Sign up to set email alerts
|

High‐throughput screening assay for the quantification of Cer d18:1/16:0, d18:1/24:0, d18:1/24:1, d18:1/18:0, d18:1/14:0, d18:1/20:0, and d18:1/22:0 in HepG2 cells using RapidFire mass spectrometry

Abstract: Ceramides are known to be involved in various biological processes with their physiological levels elevated in various disease conditions such as diabetes, Alzheimer's, atherosclerosis. To facilitate the rapid screening of Cer d18:1/16:0, d18:1/24:0, d18:1/24:1, d18:1/18:0, d18:1/14:0, d18:1/20:0, and d18:1/22:0 inhibition in HepG2 cells, a RapidFire coupled to tandem mass spectrometry (RF-MS/MS) method has been developed. The RF platform provides an automated solid-phase extraction system that gave a throughp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…For ESI, different technologies such as the RapidFire system in BLAZE‐mode (Bretschneider et al , 2019 ) or ADE‐OPI MS approach have been described for enzymatic‐type assays (Häbe et al , 2020 ; Simon et al , 2021a ). The versatility of the instrument setup allows the analysis of many different biomolecules including lipids (Highkin et al , 2011 ; Dittakavi et al , 2020 ), peptides (Hutchinson et al , 2011 ; Liddle et al , 2020 ), and metabolites (Soulard et al , 2008 ; Maxine et al , 2009 ), from a wide range of matrix systems including blood, plasma (Highkin et al , 2011 ; Bretschneider et al , 2017 ) and cell lysates (Gordon et al , 2016 ; Dittakavi et al , 2020 ). Ambient ionization, such as desorption electrospray ionization (DESI), which commonly does not require sample preparation, is a new and attractive alternative for HT analysis.…”
Section: Mass Spectrometry Screening Assays For Drug Discoverymentioning
confidence: 99%
“…For ESI, different technologies such as the RapidFire system in BLAZE‐mode (Bretschneider et al , 2019 ) or ADE‐OPI MS approach have been described for enzymatic‐type assays (Häbe et al , 2020 ; Simon et al , 2021a ). The versatility of the instrument setup allows the analysis of many different biomolecules including lipids (Highkin et al , 2011 ; Dittakavi et al , 2020 ), peptides (Hutchinson et al , 2011 ; Liddle et al , 2020 ), and metabolites (Soulard et al , 2008 ; Maxine et al , 2009 ), from a wide range of matrix systems including blood, plasma (Highkin et al , 2011 ; Bretschneider et al , 2017 ) and cell lysates (Gordon et al , 2016 ; Dittakavi et al , 2020 ). Ambient ionization, such as desorption electrospray ionization (DESI), which commonly does not require sample preparation, is a new and attractive alternative for HT analysis.…”
Section: Mass Spectrometry Screening Assays For Drug Discoverymentioning
confidence: 99%
“…Finally, there have also been multiple reports where RapidFire assays have been successfully adapted to enable screening of highly complex samples, including cells, 38,39 plasma, and whole blood. 40 In a particularly interesting example, Bretschneider et al demonstrated the ability to measure the activity of autotaxin, an enzyme that catalyzes the hydrolysis of lysophosphatidylcholines into lysophosphatidic acids, and which is believed to play a pathophysiological role in the development of diseases such as cancer, fibrosis, arthritis, and multiple sclerosis.…”
Section: Rapidfire-msmentioning
confidence: 99%