2016
DOI: 10.1152/ajpheart.00793.2015
|View full text |Cite
|
Sign up to set email alerts
|

High-throughput drug profiling with voltage- and calcium-sensitive fluorescent probes in human iPSC-derived cardiomyocytes

Abstract: Bedut S, Seminatore-Nole C, Lamamy V, Caignard S, Boutin JA, Nosjean O, Stephan JP, Coge F. High-throughput drug profiling with voltage-and calcium-sensitive fluorescent probes in human iPSC-derived cardiomyocytes. Am J Physiol Heart Circ Physiol 311: H44 -H53, 2016. First published May 3, 2016 doi:10.1152/ajpheart.00793.2015.-Cardiomyocytes derived from human embryonic stem cells (hESCs) or induced pluripotent stem cells (hiPSCs) are increasingly used for in vitro assays and represent an interesting opportun… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
51
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(59 citation statements)
references
References 26 publications
2
51
0
1
Order By: Relevance
“…CaT amplitude was very stable across different measurements of the plate, in contrast to CaT duration which was highly dependent on the conditions of the plate (i.e. temperature, % CO 2 ) and tended to increase during measurement, as also reported previously 18 . This emphasizes the importance of maintaining the plate as closely as possible to incubation conditions during plate readings and designing an assay flow and analysis to avoid detecting false positives.…”
Section: Discussionsupporting
confidence: 85%
“…CaT amplitude was very stable across different measurements of the plate, in contrast to CaT duration which was highly dependent on the conditions of the plate (i.e. temperature, % CO 2 ) and tended to increase during measurement, as also reported previously 18 . This emphasizes the importance of maintaining the plate as closely as possible to incubation conditions during plate readings and designing an assay flow and analysis to avoid detecting false positives.…”
Section: Discussionsupporting
confidence: 85%
“…High-throughput optical readouts using voltage dyes, calcium dyes, or their combinations have demonstrated the utility of hESC/iPSC-CMs as a model system for such methods647. While our current system configuration cannot be directly utilized in high-throughput analysis, there is no fundamental barrier that precludes the development of such capabilities.…”
Section: Discussionmentioning
confidence: 99%
“…In contrast, Bedut et al . demonstrated reduced beating rates in hiPSC‐CMs at lower doses of ivabradine (1‐2 μM vs 3‐9 μM) (Bedut et al , 2016). Furthermore, when drug concentrations were compared among different hPSC‐CM lines, techniques or studies, the differences appear to be significant and functionally relevant (Kuusela et al , 2016).…”
Section: Limitations In Applicability Of Hipsc‐cm To Large‐scale Drugmentioning
confidence: 99%