2005
DOI: 10.1016/j.chroma.2005.09.056
|View full text |Cite
|
Sign up to set email alerts
|

High-throughput analysis of tetracycline and penicillin antibiotics in animal tissues using electrospray tandem mass spectrometry with selected reaction monitoring transition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
25
0
1

Year Published

2006
2006
2015
2015

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 66 publications
(27 citation statements)
references
References 19 publications
0
25
0
1
Order By: Relevance
“…Meclveclocici et al (3) developed a HPLC method, using aqueous phosphate as the mobile phase, for the determination of 0.1-5 μg/mL penicillin. MS has been widely used in penicillin assays and it is often integrated with other techniques, such as liquid chromatography-mass spectrometry (LC-MS) (4-6) and electrospray-mass spectrometry (E-MS) (7)(8)(9). By LC-MS, the quantification limit was estimated to be 5 μg/kg penicillin (6).…”
Section: Introductionmentioning
confidence: 99%
“…Meclveclocici et al (3) developed a HPLC method, using aqueous phosphate as the mobile phase, for the determination of 0.1-5 μg/mL penicillin. MS has been widely used in penicillin assays and it is often integrated with other techniques, such as liquid chromatography-mass spectrometry (LC-MS) (4-6) and electrospray-mass spectrometry (E-MS) (7)(8)(9). By LC-MS, the quantification limit was estimated to be 5 μg/kg penicillin (6).…”
Section: Introductionmentioning
confidence: 99%
“…Most of the sample preparation protocols involve extraction with an aqueous solution, an organic solvent or mixtures of them and further purification by SPE on C 18 silica-based sorbents [12, 13, 17, 18, 23 -26], on divinylbenzene-co-Nvinylpyrrolidone polymeric sorbents [22] or by ultrafiltration [28].…”
Section: Introductionmentioning
confidence: 99%
“…Some of them are based on the determination of tetracycline by flow analysis coupled to a capillary electrophoresis system in water (5), by flow-injection analysis with pulsed amperometric detection (6) or spectrophotometric detection (7) in pharmaceutical formulations, and with fluorescence detection in serum (8) or chemiluminiscence detection in pharmaceutical formulations (9). Others are based on HPLC measurements, with spectrophotometric detection in shrimps and milk (10) and in fish muscle (11), with amperometric detection in shrimps (12), with electrospray tandem mass spectrometry in animal tissues (13) and in foods (14), with fluorescence detection in water (15), honey (16), salmon (17) and other biological materials (18). In addition, determinations of tetracycline have been carried out by means of capillary electrophoresis in milk and plasma (19) and in pharmaceutical formulations (20), by means of molecular fluorescence in water (21,22) and in blood serum (23).…”
mentioning
confidence: 99%