Abstract:A series single-pass compression tests of HRB400 slab under the circumstances of different deformation temperature and deformation rate are carried out with Gleeble-1500D thermal simulation testing machine. The experimental results shows as follows. The true stress-true strain curves of the compression process are got from the tests. The state activation energy is 353.542kJ/mol and a mathematical model of high-temperature rheological stress is established. The calculated results by the rheological model are co… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.