2001
DOI: 10.1109/77.919436
|View full text |Cite
|
Sign up to set email alerts
|

High-T/sub c/ superconducting surface coil for 2 tesla magnetic resonance imaging of small animals

Abstract: T h e p e r f o r m a n c e o f s m a I I-v o I u m e Magnetic Resonance Imaging (M R I) d e p e n d s on t h e s y s t e m n o i s e determined by noise of a probe and/or of a preamplifier (not by the body noise). Several demonstrations confirmed that, for selected applications, high-TC superconductor MRI receiver coils have superior properties to those of comparable copper coils. W e report on the outstanding performance of modified twin horseshoe Y B C O r f surface probes in a 2 Tesla s c a n n e r operati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2003
2003
2016
2016

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…Compared with HTS coils [9][10][11][12], LN 2 cooled coils provide the advantages of simpler array construction and flexible three-dimensional shapes for volumetric coverage. Although flexible HTS tapes/wires have also been used for RF coils, their superconducting properties degrade rapidly in a high magnetic field [1].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Compared with HTS coils [9][10][11][12], LN 2 cooled coils provide the advantages of simpler array construction and flexible three-dimensional shapes for volumetric coverage. Although flexible HTS tapes/wires have also been used for RF coils, their superconducting properties degrade rapidly in a high magnetic field [1].…”
Section: Discussionmentioning
confidence: 99%
“…The y include copper coils cooled to liquid nitrogen (LN 2 ) temperature (77 K) [1][2][3][4][5][6] or to liquid helium temperat ure (4.2 K) [7,8] and hightemperature superconducting (HTS) coils [9][10][11][12]. Cryogenic cooling reduces RF coil noise through the lowering of coil resistance (R C ) and coil temperature.…”
Section: Introductionmentioning
confidence: 99%
“…The discovery and development of high-temperature superconducting (HTS) materials has resulted in several attempts to build practical probes with improved SNR. Indeed, preliminary studies have shown that for selected applications where the MRI system noise is in the coil loss regime (low-field MRI, highfield microscopy, and small-volume MRI) HTS MRI receiver coils perform significantly better than comparable copper coils [4]- [7].…”
Section: Introductionmentioning
confidence: 99%
“…Compared with the GE pulse sequence, the SE image protocol requires uniform tip angle to achieve 180 degree magnetisation inversion. Therefore the SE pulse is rarely adopted by other cryogenic coil techniques [26].…”
Section: K)mentioning
confidence: 99%