2004
DOI: 10.1016/j.physletb.2003.12.002
|View full text |Cite
|
Sign up to set email alerts
|

High statistics study of the K−→π0μ−ν decay

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
35
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 55 publications
(38 citation statements)
references
References 9 publications
3
35
0
Order By: Relevance
“…• K 3 shapes: We take the value of log C from the latest Flavianet update [43] and the tensor term for the muonic mode from the ISTRA+ analysis [63]. We assume these bounds will hold in a combined fit, and we neglect the correlations of log C,…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…• K 3 shapes: We take the value of log C from the latest Flavianet update [43] and the tensor term for the muonic mode from the ISTRA+ analysis [63]. We assume these bounds will hold in a combined fit, and we neglect the correlations of log C,…”
Section: Methodsmentioning
confidence: 99%
“…These parameters are customarily fitted to the kinematic distributions of the decay (or Dalitz plot) [63][64][65][66][67][68][69][70], allowing for a calculation the phase-space integral (see next subsection). The Taylor-expansion parametrization introduces a number of parameters which can not be always determined experimentally free of ambiguities and more efficient parametrizations have been proposed [1,11,20,32], incorporating physical constraints to reduce the number of independent parameters.…”
Section: Kinematical Distributionmentioning
confidence: 99%
“…Dealing with these decays is much harder because: a) -the branching ratio is smaller, resulting in reduced statistics, b) -the E π or t range in the decay is smaller, c) -it is in general harder to obtain an undistorted spectrum and d) -more parameters are necessary. This is quite well evidenced by the wide range of answers obtained by different experiments [48,53,54,52]. Assuming that both scalar and vector FF are given by quadratic polynomials as in Eq.…”
Section: E2 K µ3 Decaysmentioning
confidence: 72%
“…Finally, we note that no information concerning the treatment of radiative corrections is given in Ref. [53]. Failure to account for radiative effects could result in a noticeable systematic shift in the slope results.…”
Section: D2 Input Datamentioning
confidence: 93%
See 1 more Smart Citation