2021
DOI: 10.1101/2021.01.19.427254
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

High-speed large-scale 4D activities mapping of moving C. elegans by deep-learning-enabled light-field microscopy on a chip

Abstract: We report a novel fusion of microfluidics and light-field microscopy, to achieve high-speed 4D (space + time) imaging of moving C. elegans on a chip. Our approach combines automatic chip-based worm loading / compartmentalization / flushing / reloading with instantaneous deep-learning light-field imaging of moving worm. Taken together, we realized intoto image-based screening of wild-type and uncoordinated-type worms at a volume rate of 33 Hz, with sustained observation of 1 minute per worm, and overall through… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 32 publications
0
1
0
Order By: Relevance
“…With faster imaging technologies such as lightfield or lightsheet imaging (Voleti et al 2019;Zhu et al 2021) allowing brain imaging at up to 26 VPS, the true limitation for measurement is frequently the brightness of the indicator rather than the speed of acquisition (Kato et al 2015;Hallinen et al 2021;Atanas et al 2022). Accordingly, faster and brighter indicators would positively impact these measurements in two ways, as they could either enable imaging of neurons driving faster behaviors, such as head swings, pharyngeal pumping and the activity of the spiking motoneurons (Gao and Zhen 2011;Hendricks et al 2012;Trojanowski et al 2016;Atanas et al 2022), or alternatively enable longer measurements due to the lower photobleaching expected.…”
Section: Introductionmentioning
confidence: 99%
“…With faster imaging technologies such as lightfield or lightsheet imaging (Voleti et al 2019;Zhu et al 2021) allowing brain imaging at up to 26 VPS, the true limitation for measurement is frequently the brightness of the indicator rather than the speed of acquisition (Kato et al 2015;Hallinen et al 2021;Atanas et al 2022). Accordingly, faster and brighter indicators would positively impact these measurements in two ways, as they could either enable imaging of neurons driving faster behaviors, such as head swings, pharyngeal pumping and the activity of the spiking motoneurons (Gao and Zhen 2011;Hendricks et al 2012;Trojanowski et al 2016;Atanas et al 2022), or alternatively enable longer measurements due to the lower photobleaching expected.…”
Section: Introductionmentioning
confidence: 99%