2022
DOI: 10.1021/acs.analchem.1c04309
|View full text |Cite
|
Sign up to set email alerts
|

High-Sensitivity Silicon Cantilever-Enhanced Photoacoustic Spectroscopy Analyzer with Low Gas Consumption

Abstract: A silicon cantilever-enhanced photoacoustic spectroscopy (PAS)based trace gas analyzer with low gas consumption is presented. A silicon cantilever-based fiber-optic Fabry−Perot (F−P) interferometric acoustic sensor with a compact structure and high sensitivity is designed for photoacoustic signal detection. The non-resonant photoacoustic cell (PAC) is a cylindrical copper tube with a volume of 0.56 mL. A near-infrared laser with a center wavelength of 1532.83 nm amplified using an erbium-doped fiber applicatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 45 publications
(17 citation statements)
references
References 44 publications
0
15
0
Order By: Relevance
“…An Allan-Werle analysis [54] , [55] , [56] , [57] has been realized by filling the designed sensor with pure N 2 and continuously measuring the PA signals for a long time. The Allan-Werle deviation calculated under the pure N 2 background is gained and presented in Fig.…”
Section: Experimental System and Resultsmentioning
confidence: 99%
“…An Allan-Werle analysis [54] , [55] , [56] , [57] has been realized by filling the designed sensor with pure N 2 and continuously measuring the PA signals for a long time. The Allan-Werle deviation calculated under the pure N 2 background is gained and presented in Fig.…”
Section: Experimental System and Resultsmentioning
confidence: 99%
“…When the integration time (IT) of the three VLIAs is 1 s, the deviations are 1.28, 1.52, and 1.19 pm for CH 4 , C 2 H 2 , and H 2 S, respectively, and based on the detection sensitivities of the gas sensor to CH 4 , C 2 H 2 , and H 2 S, the MDLs for CH 4 , C 2 H 2 , and H 2 S are estimated to be 167, 47.5, and 1597 ppb, respectively. The results of the Allan-Werle analysis are shown in Figure a–c. When the three ITs are, respectively, 100 s, the corresponding MDLs are 16.6, 4.8, and 162 ppb for CH 4 , C 2 H 2 , and H 2 S. Table summarizes the performance parameters of previously developed sensors based on PAS for single trace gas (CH 4 , C 2 H 2 , and H 2 S) and multiple trace gas (CH 4 and C 2 H 2 ) detection as a comparison to demonstrate the performance of the designed all-optical miniaturized PA sensor.…”
Section: Methodsmentioning
confidence: 99%
“…Michelson interferometer has high sensitivity and good stability, but the bulky volume and high cost limit its application in some specific fields. CEPAS based on Fabry-Perot interferometer is relatively compact [50] , [51] , [52] , [53] , [54] , [55] , [56] , [57] , [58] , [59] , [60] , [61] , [62] . A Fabry-Perot cavity is formed between the end facet of the fiber and the free end of the cantilever.…”
Section: Cepas Based On Different Displacement Detection Techniquesmentioning
confidence: 99%