2016
DOI: 10.1373/jalm.2016.020362
|View full text |Cite
|
Sign up to set email alerts
|

High-Sensitivity Micro LC-MS/MS Assay for Serum Estradiol without Derivatization

Abstract: Background: There are considerable demands to accurately measure estradiol (E 2 ) at low concentrations (<20 pg/mL) in postmenopausal women, men, pediatric patients, and patients receiving breast cancer treatment. Most current high-sensitivity LC-MS/MS E 2 methods require large sample volumes and involve complex sample preparations with dansyl chloride derivatization. Our study aims to develop a high-sensitivity, underivatized method using micro LC-MS/MS to reliably measure E 2 concentrations below 5 pg/mL by … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 19 publications
(5 citation statements)
references
References 39 publications
(55 reference statements)
1
4
0
Order By: Relevance
“…More specific assays (ie, LC or GC with MS) have less cross-reactivity with other steroidal-like molecules and typically yield lower estradiol values than less specific assays with inherently greater cross-reactivities (ie, RIA or ELISA). 9,54 Our current review is consistent with previous findings demonstrating that many of the most recently developed highly specific assays can detect or quantify systemic estradiol as low as 0.1 to 2.7 pg/mL using LC/MS/MS or LC/MS, [37][38][39][40][41]43,44,[55][56][57][58][59][60][61] and 1 to 5 pg/mL using GC/MS/MS or GC/MS. 26,28,29,42 Indeed, the goal of sensitivity has been SYSTEMIC ESTRADIOL WITH VAGINAL ESTROGENS to develop assays detecting <5 pg/mL of estradiol for measuring estradiol in serum of postmenopausal women.…”
Section: Discussionsupporting
confidence: 89%
“…More specific assays (ie, LC or GC with MS) have less cross-reactivity with other steroidal-like molecules and typically yield lower estradiol values than less specific assays with inherently greater cross-reactivities (ie, RIA or ELISA). 9,54 Our current review is consistent with previous findings demonstrating that many of the most recently developed highly specific assays can detect or quantify systemic estradiol as low as 0.1 to 2.7 pg/mL using LC/MS/MS or LC/MS, [37][38][39][40][41]43,44,[55][56][57][58][59][60][61] and 1 to 5 pg/mL using GC/MS/MS or GC/MS. 26,28,29,42 Indeed, the goal of sensitivity has been SYSTEMIC ESTRADIOL WITH VAGINAL ESTROGENS to develop assays detecting <5 pg/mL of estradiol for measuring estradiol in serum of postmenopausal women.…”
Section: Discussionsupporting
confidence: 89%
“…The study by Yi et al (1) affirms my confidence in stating that the second golden age of clinical chemistry is upon us once again. I am excited and grateful because, 30 years after starting my career in clinical chemistry, I am back in the real chemistry game, and patients will benefit from these efforts.…”
mentioning
confidence: 76%
“…Serum LH and FSH were measured by immunofluorometric assays (Delphia®, Wallach, Finland). Serum testosterone was measured by direct radioimmunoassay (Diagnostic Products Corporation, DPC, Coat-A-Count®, Los Angeles, CA, USA), estradiol by a post-extraction radioimmunoassay (Pantex®, Santa Monica, CA, USA), and 17-hydroxyprogesterone (17OHP) by post-chromatographic radioimmunoassay in the University of Chicago Hospital Laboratories (UCHL) [11]; these steroid radio-immunoassays have been validated against liquid chromatography-mass spectrometry methods [12, 13]. Other hormone levels were measured by commercially available assays at UCHL, Mayo Medical Laboratories (Rochester, MN, USA), or Esoterix (Calabasas Hills, CA, USA).…”
Section: Methodsmentioning
confidence: 99%