2022
DOI: 10.1109/jsen.2021.3121447
|View full text |Cite
|
Sign up to set email alerts
|

High Sensitivity Coreless Fiber Surface Plasmon Resonance Sensor Based on Au Nano Biconical Particles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 46 publications
0
5
0
Order By: Relevance
“…The optical fiber needs to be pretreated before the experiment. The prepared structures were first soaked in 1% PDDA for 2 h. The surface of the PDDA-treated fiber was positively charged . The steps of lipase immobilization are listed in Figure .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The optical fiber needs to be pretreated before the experiment. The prepared structures were first soaked in 1% PDDA for 2 h. The surface of the PDDA-treated fiber was positively charged . The steps of lipase immobilization are listed in Figure .…”
Section: Methodsmentioning
confidence: 99%
“…The prepared structures were first soaked in 1% PDDA for 2 h. The surface of the PDDA-treated fiber was positively charged. 31 The steps of lipase immobilization are listed in Figure 2. The fiber surface was rinsed with anhydrous ethanol and pure water, and the spectrum at this point was used as a reference.…”
Section: Lipase Immobilizationmentioning
confidence: 99%
“…This occurs when the sensing layer is under the influence of total internal reflection (TIR). The wavelength-dependent RI of TiO 2 can be expressed by Equation ( 3 ) [ 7 ]. Here, is the operating wavelength.…”
Section: Numerical Analysismentioning
confidence: 99%
“…Sensing techniques based on Mach Zehnder interferometer, fiber grating, spectroscopy, and wavelength division multiplexing are the most demanding approaches. The optical light intensity has been used for prominent sensing techniques such as colorimetric [ 5 ], light scattering [ 6 ], surface plasmon resonance (SPR) sensors [ 7 ], scattering sensors [ 8 ], electrochemiluminescence sensors [ 9 ], fluorescent sensors [ 10 ], and so on. Various analyses were performed, and the relative sensitivity of 45% was noted for identifying hazardous chemicals that are harmful to the human body [ 11 ].…”
Section: Introductionmentioning
confidence: 99%
“…As a special type of optical fiber, coreless fibers exhibit unique transmission characteristics as the sensing part of the NCF is in direct contact with the external environment. In recent years, the NCF has been commonly coated with a metal film to excite surface plasmon resonance [24,25]. All these methods are precise and sensitive; however, in case of a high RI sensitivity, these methods are unable to simultaneously ensure the advantages of simple manufacturing, good robustness, and low cost.…”
Section: Introductionmentioning
confidence: 99%