High selective potentiometric sensor for determination of nanomolar con-centration of Cu(II) using a polymeric electrode modified by a graphene/7,7,8,8-tetracyanoquinodimethane nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 42 publications
0
9
0
Order By: Relevance
“…To explore the novelty of this work, comparison of the proposed sensors with other solid-contact Cu 2+ -ISEs previously reported is also given in Table 5. The table clearly indicated good enhancement in the behavior of the proposed copper electrode in terms of the detection limit and linear range [33,35,36,37,41,42,43,44], slope [34,44] and selectivity [33,34,42].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…To explore the novelty of this work, comparison of the proposed sensors with other solid-contact Cu 2+ -ISEs previously reported is also given in Table 5. The table clearly indicated good enhancement in the behavior of the proposed copper electrode in terms of the detection limit and linear range [33,35,36,37,41,42,43,44], slope [34,44] and selectivity [33,34,42].…”
Section: Resultsmentioning
confidence: 99%
“…One is based on the use of 1-ethyl-3-methyl imidazolium chloride as an ionic liquid doped with the ionophore [33]. Nano-structured carbon materials are also used as solid contact materials-based solid-contact Cu 2+ -ISE such as carboxylic multi-walled carbon nanotubes [34], multi-walled carbon nanotubes (MWCNT) [35], single-walled carbon nanotubes (MWCNT) [36] and graphen (GR) and grapheme oxide (GO) [37]. Single-piece solid-contact Cu 2+ -ISEs have different advantages such as ease of miniaturization, simplicity, stability and disposability.…”
Section: Introductionmentioning
confidence: 99%
“…[33][34][35] All of these merits make potentiometric approaches the most favorable approach for Cu 2+ assessment. Although there are many solid electrodes for copper measurement in the literature, [36][37][38][39][40][41][42][43][44][45] they have been applied in environmental analyses. There are no reported sensors for copper determination based on the paper as a solid support for point-of-care purposes.…”
Section: Introductionmentioning
confidence: 99%
“…Copper is likewise a fundamental component for hemoglobin amalgamation, rectify nerve working, and bone improvement, Copper insufficiency causes ischemic coronary illness, iron deficiency, and abnormal wool growth (3). Many techniques are used to determine copper including atomic absorption spectrometry (4)(5)(6), potentiometry (7)(8)(9)(10)(11), inductive coupled plasma-emission spectrometry (12), inductive coupled plasma-mass spectrometry (13), and flow injection catalytic photometric method (14).…”
Section: Introductionmentioning
confidence: 99%