2021
DOI: 10.1016/j.xjon.2021.10.001
|View full text |Cite
|
Sign up to set email alerts
|

High-risk cardiac surgery: Time to explore a new paradigm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
15
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(15 citation statements)
references
References 31 publications
(44 reference statements)
0
15
0
Order By: Relevance
“…The TandemHeart is an external temporary device based on the insertion of a cannula (21-Fr cannula) through the interatrial septum to the left atrium. It is composed of three subsystems (a transseptal cannula, the centrifugal blood pump, and an arterial cannula) [ 8 , 39 ]. Oxygenated blood is pumped out from the left atrium to a centrifugal pump which continuously returns the blood to the femoral artery through a 12 Fr cannula or to the iliac artery through a 5–17 Fr cannula ( Figure 2 ).…”
Section: Cardioprotective Devices That Unload the Heartmentioning
confidence: 99%
See 1 more Smart Citation
“…The TandemHeart is an external temporary device based on the insertion of a cannula (21-Fr cannula) through the interatrial septum to the left atrium. It is composed of three subsystems (a transseptal cannula, the centrifugal blood pump, and an arterial cannula) [ 8 , 39 ]. Oxygenated blood is pumped out from the left atrium to a centrifugal pump which continuously returns the blood to the femoral artery through a 12 Fr cannula or to the iliac artery through a 5–17 Fr cannula ( Figure 2 ).…”
Section: Cardioprotective Devices That Unload the Heartmentioning
confidence: 99%
“…Oxygenated blood is pumped out from the left atrium to a centrifugal pump which continuously returns the blood to the femoral artery through a 12 Fr cannula or to the iliac artery through a 5–17 Fr cannula ( Figure 2 ). This device is capable of generating a continuous flow of up to 4 L/min output [ 8 , 39 ]. Moreover, the addition of an oxygenator makes it possible for respiratory support [ 64 ].…”
Section: Cardioprotective Devices That Unload the Heartmentioning
confidence: 99%
“…Goldstein and Soltesz 1 present a preliminary report on the use of the advanced Impella support device (Impella version 5.5; Abiomed, Danvers, Mass) for preemptive ventricular support in high-risk patients undergoing operation in the setting of significant ventricular compromise. When preexisting stunned, hibernating, and/or acutely ischemic myocardium is subjected to the pathophysiology of the cardiopulmonary bypass circuit, to the ischemia mandated by crossclamping, and to the possibility of suboptimal cardioprotection, the result is often a dangerous combination of vasoplegia and postoperative low cardiac output.…”
mentioning
confidence: 99%
“…Other rather extreme measures like left ventricular assist devices and transplantation are final steps in this decision algorithm and these are even less likely to provide a satisfactory outcome in the urgent setting of low cardiac output and severe left ventricular dysfunction after operation. In response to postcardiotomy shock, Goldstein and Soltesz 1 present an intriguing option: The paradigm of preventive support with preemptive ventricular unloading.…”
mentioning
confidence: 99%
See 1 more Smart Citation