1997
DOI: 10.1063/1.1147977
|View full text |Cite
|
Sign up to set email alerts
|

High resolution threshold and pulsed field ionization photoelectron spectroscopy using multi-bunch synchrotron radiation

Abstract: High-resolution state-selected ion-molecule reaction studies using pulsed field ionization photoelectronsecondary ion coincidence method Rev. Sci. Instrum. 74, 4096 (2003); 10.1063/1.1599071High-resolution pulsed field ionization photoelectron-photoion coincidence spectroscopy using synchrotron radiation Rev.A study of the SO molecule with photoelectron spectroscopy using synchrotron radiationWe have demonstrated a resolution of 0.8 meV ͓full width at half-maximum ͑FWHM͔͒ for threshold photoelectron measuremen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
54
1

Year Published

1998
1998
2007
2007

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 71 publications
(56 citation statements)
references
References 24 publications
(37 reference statements)
1
54
1
Order By: Relevance
“…The dark-gap PFI-PE scheme using the high-resolution monochromatized VUV undulator synchrotron radiation at the ALS has been described in detail. [24][25][26][27][28][29] Briefly, the ALS storage ring in the multibunch mode has a dark gap of 102 ns in every period of 656 ns. The PFI electric field pulse ͑2.2 V / cm, 40 ns width͒ was applied 10 ns after the beginning of the dark gap in every ALS ring period.…”
Section: Methodsmentioning
confidence: 99%
“…The dark-gap PFI-PE scheme using the high-resolution monochromatized VUV undulator synchrotron radiation at the ALS has been described in detail. [24][25][26][27][28][29] Briefly, the ALS storage ring in the multibunch mode has a dark gap of 102 ns in every period of 656 ns. The PFI electric field pulse ͑2.2 V / cm, 40 ns width͒ was applied 10 ns after the beginning of the dark gap in every ALS ring period.…”
Section: Methodsmentioning
confidence: 99%
“…23,24 vuv from synchrotron radiation source has also been utilized for one-photon ZEKE/MATI. 17,25 Availability of vuv with continuously variable wavelength is its advantage even though monochromaticity of the light is not as good as for the laser-based sources.…”
Section: Introductionmentioning
confidence: 99%
“…1,10,12,[22][23][24][25] In the present experiment, Ar was used in the gas filter to suppress higher undulator harmonics with photon energies (hν) greater than 15.76 eV.…”
Section: Methodsmentioning
confidence: 99%