2014
DOI: 10.1118/1.4894704
|View full text |Cite
|
Sign up to set email alerts
|

High‐resolution three‐dimensional visualization of the rat spinal cord microvasculature by synchrotron radiation micro‐CT

Abstract: The results of this study indicated that SRµCT scanning could provide higher resolution images of the vascular network of the spinal cord. This modality also has the potential to serve as a powerful imaging tool for the investigation of morphology changes in the 3D angioarchitecture of the neurovasculature in preclinical research.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
29
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 37 publications
(29 citation statements)
references
References 36 publications
0
29
0
Order By: Relevance
“…These high precision and high fidelity 3D structural parameters further enable our study of the minute modification of renal microvascularture 5255 . As a benefit of the superior performance, for example, that the number of microvessels determined by our imaging method was significantly higher than that of lab-based micro CTs 56 .…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…These high precision and high fidelity 3D structural parameters further enable our study of the minute modification of renal microvascularture 5255 . As a benefit of the superior performance, for example, that the number of microvessels determined by our imaging method was significantly higher than that of lab-based micro CTs 56 .…”
Section: Discussionmentioning
confidence: 98%
“…S1, for example showing an X-ray image of a nanofabricated Au test pattern) with very fast imaging acquisition and processing. Our X-ray imaging platform also features nanoscale resolution and has been successfully applied to investigate tumor angiogenesis at tissue and cell level 2026 . For this work specifically, the microtomography is suitable for exploring the kidney microvasculature 2729 and nanotomography supplemented the detailed examination.…”
Section: Introductionmentioning
confidence: 99%
“…35 The spatial resolution of SRA can reach submicrons, approximately 1000 times higher than that of conventional X-ray absorption imaging, and it can be used for high-resolution imaging of the whole middle cerebral artery territory blood supply in living rodents. 53,54 Vessel density is an indicator of microvascular perfusion. Our results showed that NBP treatment increased the perfused vessel density.…”
Section: Discussionmentioning
confidence: 99%
“…All the relevant results are compatible, so the theoretically derived relative accuracy defined by equation (4) was verified and seems to be valid. Figure 8 shows theoretical accuracy ("Declared accuracy") and true accuracy 7 with errorbars presenting variance of measurements ("True accuracy"). Entire set of measured values stayed below the declared accuracy, what shows, that this accuracy estimation is very pessimistic, and real accuracy seems to be better ("Apparent real accuracy").…”
Section: Resultsmentioning
confidence: 99%
“…Finally, computer 3D models are, due to its plasticity, becoming more and more used for visualization of objects, which are unreachable (contaminated, dangerous or remote areas) [5], [6] or environments, which are invisible without invasive surgery (human inner structures) [7]. Another objects are visible, but its important details are too tiny (human outer structures) and it is necessary to enlarge them plastically [8].…”
Section: Introductionmentioning
confidence: 99%