High-resolution spatial and temporal measurements of particulate organic carbon flux using thorium-234 in the northeast Pacific Ocean during the EXport Processes in the Ocean from RemoTe Sensing field campaign

Abstract: The EXport Processes in the Ocean from RemoTe Sensing (EXPORTS) program of National Aeronautics and Space Administration focuses on linking remotely sensed properties from satellites to the mechanisms that control the transfer of carbon from surface waters to depth. Here, the naturally occurring radionuclide thorium-234 was used as a tracer of sinking particle flux. More than 950 234Th measurements were made during August–September 2018 at Ocean Station Papa in the northeast Pacific Ocean. High-resolution vert… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
42
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

3
2

Authors

Journals

citations
Cited by 20 publications
(46 citation statements)
references
References 58 publications
4
42
0
Order By: Relevance
“…After acidification and 230 Th addition, samples are allowed to equilibrate for at least 6 h, but may be stored for up to several days prior to additional processing. Note that the 6-h equilibration time is less than the 8-12 h suggested in initial method development [25,30], but no significant difference is found in the 234 Th signal or 230 Th yield from equilibration time reduction [31]. Using a smaller volume not only reduces filtration time (~ 9 h average for 4 L samples, ~ 2 h average for 2 L samples in offshore water), but it is also advantageous when multiple groups are sharing water collected from a standard 10-12 L Niskin bottle.…”
Section: Updated Method: Results and Discussion For Methods Improvementsmentioning
confidence: 99%
See 4 more Smart Citations
“…After acidification and 230 Th addition, samples are allowed to equilibrate for at least 6 h, but may be stored for up to several days prior to additional processing. Note that the 6-h equilibration time is less than the 8-12 h suggested in initial method development [25,30], but no significant difference is found in the 234 Th signal or 230 Th yield from equilibration time reduction [31]. Using a smaller volume not only reduces filtration time (~ 9 h average for 4 L samples, ~ 2 h average for 2 L samples in offshore water), but it is also advantageous when multiple groups are sharing water collected from a standard 10-12 L Niskin bottle.…”
Section: Updated Method: Results and Discussion For Methods Improvementsmentioning
confidence: 99%
“…A 2 L sample volume was originally suggested by Benitez-Nelson et al [25], but 4 L sample sizes continued to be popular because of the lower beta counting time required with larger volumes. The 2 L method detailed here, however, has proven to produce similarly high-quality results [31], and is manageable when sufficient beta counting capacity is available at-sea or on-land shortly after collection. This 2 L method is based upon the formation of a MnO 2 precipitate (Fig.…”
Section: Revised 2 L Methods Overviewmentioning
confidence: 99%
See 3 more Smart Citations