1990
DOI: 10.1063/1.1141122
|View full text |Cite
|
Sign up to set email alerts
|

High-resolution pulsed dye laser calibration in the 500–350 nm region using iodine atlas reference lines

Abstract: Articles you may be interested inPolychromators in the ultraviolet/infrared (350-750 nm) spectral range for high-resolution, high sensitivity plasma spectroscopy (abstract) Rev. Sci.A simple, inexpensive method for precisely calibrating high-resolution, pulsed dye lasers in the 500-350 nm wavelength region has been devised. The residual portion of the laser beam exiting from an experiment is Raman shifted to longer wavelengths in a high-pressure hydrogen cell. The Stokes shifted output is used to excite laser … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0

Year Published

1991
1991
2004
2004

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 48 publications
(19 citation statements)
references
References 20 publications
0
19
0
Order By: Relevance
“…The laser radiation, after being stimulated-Raman shifted 4155.225 cm Ϫ1 to the red in a high-pressure H 2 cell, 6 was calibrated ͑consistently and accurately͒ using either the optogalvanic effect for Ne transitions 7 ͑corrected to vacuum͒ in a low-pressure hollow-cathode lamp, 7 or fluorescence from I 2(g) transitions 8 in an evacuated cell filled with I 2(s) at room temperature. Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The laser radiation, after being stimulated-Raman shifted 4155.225 cm Ϫ1 to the red in a high-pressure H 2 cell, 6 was calibrated ͑consistently and accurately͒ using either the optogalvanic effect for Ne transitions 7 ͑corrected to vacuum͒ in a low-pressure hollow-cathode lamp, 7 or fluorescence from I 2(g) transitions 8 in an evacuated cell filled with I 2(s) at room temperature. Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The high-resolution spectra were calibrated to an accuracy of Ϯ0.005 cm Ϫ1 using the I 2 LIF-Raman shifting technique described elsewhere. 20 In all cases, the LIF spectra and the calibration signals were digitized and recorded simultaneously on a data acquisition system of our own design. 21 Fluorescence decay curves were measured under collision-free conditions with the excitation laser 38 mm downstream of the electric discharge flow channel.…”
Section: Methodsmentioning
confidence: 99%
“…* '~bservation of laer induced fluorescence from 11 c m often pmvîde a suitable calibration for dye lasers. However, this is over a timited range of the spectnim [138], and the &ne density is so hi& that individual transitions are not casily rcsolvcd with pulsed dye h . Fluence directeci into larnp was x 10 pJ/pulse, focused from a collimated beam width of 1 mm using a 25 cm focal length lens.…”
Section: (Fts)mentioning