High resolution polarimeter-interferometer system for fast equilibrium dynamics and MHD instability studies on Joint-TEXT tokamak (invited)

Abstract: A high-performance Faraday-effect polarimeter-interferometer system has been developed for the J-TEXT tokamak. This system has time response up to 1 μs, phase resolution < 0.1° and minimum spatial resolution ∼15 mm. High resolution permits investigation of fast equilibrium dynamics as well as magnetic and density perturbations associated with intrinsic Magneto-Hydro-Dynamic (MHD) instabilities and external coil-induced Resonant Magnetic Perturbations (RMP). The 3-wave technique, in which the line-integrated Fa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
50
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(50 citation statements)
references
References 21 publications
0
50
0
Order By: Relevance
“…The eddy current in the vacuum vessel decreases the field amplitude of 3/1 component to about 0.29 Gs/kA at plasma edge for fRMP = 5.3 kHz. In the experiment, the electron density is measured by multi-channel polarimeter-interferometer (POLARIS) [36], which views the plasma vertically by 14 channels with the impact positions ranging from R = 0.84 m to 1.29 m as shown in figure 2, and the spatial temporal resolution are 30 mm and 1 s. The electron density provided by the channel at/around R = 1.05 m is used to interpret the experimental results in the context.…”
Section: Methodsmentioning
confidence: 99%
“…The eddy current in the vacuum vessel decreases the field amplitude of 3/1 component to about 0.29 Gs/kA at plasma edge for fRMP = 5.3 kHz. In the experiment, the electron density is measured by multi-channel polarimeter-interferometer (POLARIS) [36], which views the plasma vertically by 14 channels with the impact positions ranging from R = 0.84 m to 1.29 m as shown in figure 2, and the spatial temporal resolution are 30 mm and 1 s. The electron density provided by the channel at/around R = 1.05 m is used to interpret the experimental results in the context.…”
Section: Methodsmentioning
confidence: 99%
“…For this reason, almost all other machines use wavelengths larger than 100 lm for poloidal polarimetry measurements. For example, ASDEX Upgrade uses the same k ¼ 195 lm deuterium cyanide (DCN) lasers for both interferometry and polarimetry, 32,33 and both EAST and J-TEXT use k ¼ 432:5 lm formic acid (HCOOH) FIR lasers for their combined polarimeter-interferometers (POINT on EAST 21 and POLARIS on J-TEXT 37 ).…”
Section: Table IIImentioning
confidence: 99%
“…Chen et al found that through the meta-analysis of amifostine, amifostine can reduce the incidence of radiation pneumonitis in patients with nonsmall cell lung cancer receiving radiotherapy. However, regarding the dosage of amifostine and the long-term efficacy of the drug on patients after treatment, the impact on overall survival is unclear and needs further study [8].…”
Section: Introductionmentioning
confidence: 99%