2016
DOI: 10.1097/jom.0000000000000770
|View full text |Cite
|
Sign up to set email alerts
|

High-Resolution Metabolomics for Nutrition and Health Assessment of Armed Forces Personnel

Abstract: HRM analysis of serum is suitable for real-time and/or retrospective evaluation of nutrition and health status of specific military cohorts.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
20
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 36 publications
(25 citation statements)
references
References 49 publications
5
20
0
Order By: Relevance
“…Participant metabolic characteristics, derived from the metabolomics analysis of plasma, at baseline, were comparable to or within a range of previously reported values for selected features (Table 1) (50). In total, raw feature extractions yielded unique 9,377–10,583 features in both plasma and saliva, and 7,688–8,565 features in EBC.…”
Section: Resultssupporting
confidence: 81%
“…Participant metabolic characteristics, derived from the metabolomics analysis of plasma, at baseline, were comparable to or within a range of previously reported values for selected features (Table 1) (50). In total, raw feature extractions yielded unique 9,377–10,583 features in both plasma and saliva, and 7,688–8,565 features in EBC.…”
Section: Resultssupporting
confidence: 81%
“…Identities of selected plasma amino acids, metabolic intermediates, nutrition and clinical health indicators were verified by ion dissociation tandem mass spectrometry (MS/MS) and co-elution of standards (2830). Metabolite concentrations were determined using reference standardization relative to pooled reference plasma calibrated to NIST SRM1950 (28,30).…”
Section: Methodsmentioning
confidence: 99%
“…Metabolite concentrations were determined using reference standardization relative to pooled reference plasma calibrated to NIST SRM1950 (28,30). Each metabolite concentration was calculated for each sample using the ion intensity and known concentration for the respective m/z in the pooled reference sample.…”
Section: Methodsmentioning
confidence: 99%
“…Electrospray ionization was used in the positive ion mode on the Q-Exactive HF mass spectrometer operating with resolution set to 120,000 and scan range set to 85–1275 m/z (mass to charge) (Liu et al, 2016; Soltow et al, 2013). Ultra-high resolution mass spectrometry operating at 60,000 and 120,000 resolution have previously been shown to provide effective quantification of metabolites in biologic extracts (Accardi et al, 2016; Go et al, 2015b, 2015c, 2015d; Johnson et al, 2008). A 2% formic acid/acetonitrile gradient was used as described (Liu et al, 2016).…”
Section: Methodsmentioning
confidence: 99%
“…However, these do not yet have sufficient theoretical or experimental development for application to nutritional assessment. For instance, high-resolution metabolomics (HRM) (Walker et al, 2016) supports both targeted analysis of nutrients (Accardi et al, 2016) and also targeted metabolome-wide association study (MWAS) to discover metabolites and metabolic pathways that vary in association with an essential nutrient (Go et al, 2015d). In principle, this 3-step approach [ 1) experimental variation in a nutrient, 2) targeted analysis of a metabolite expected to change and 3) MWAS of the targeted metabolite] provides a way to map out diverse metabolic networks associated with variation in specific nutrients.…”
Section: Introductionmentioning
confidence: 99%