High-resolution hyperpolarized in vivo metabolic 13C spectroscopy at low magnetic field (48.7 mT) following murine tail-vein injection

Abstract: High-resolution 13C NMR spectroscopy of hyperpolarized succinate-1-13C is reported in vitro and in vivo using a clinical-scale, biplanar (80 cm-gap) 48.7 mT permanent magnet with a high homogeneity magnetic field. Non-localized 13C NMR spectra were recorded at 0.52 MHz resonance frequency over the torso of a tumor-bearing mouse every 2 seconds. Hyperpolarized 13C NMR signals with linewidths of ~3 Hz (corresponding to ~6 ppm) were recorded in vitro (2 mL in a syringe) and in vivo (over a mouse torso). Compariso… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
36
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

6
3

Authors

Journals

citations
Cited by 27 publications
(37 citation statements)
references
References 79 publications
(73 reference statements)
1
36
0
Order By: Relevance
“…Clinically relevant tracers : The hitherto limited pool of agents amenable to p H 2 -HP was recently significantly extended by SABRE [ 42 ] and PHIP-SAH [ 24 ]. By now, molecules for receptor imaging [ 43 , 44 ], succinate [ 18 , 19 , 45 ], lactate [ 11 13 , 16 ], acetate [ 24 ] were polarized, and first metabolic studies were performed with PHIP-SAH-polarized pyruvate [ 11 , 24 , 46 ].…”
Section: Discussionmentioning
confidence: 99%
“…Clinically relevant tracers : The hitherto limited pool of agents amenable to p H 2 -HP was recently significantly extended by SABRE [ 42 ] and PHIP-SAH [ 24 ]. By now, molecules for receptor imaging [ 43 , 44 ], succinate [ 18 , 19 , 45 ], lactate [ 11 13 , 16 ], acetate [ 24 ] were polarized, and first metabolic studies were performed with PHIP-SAH-polarized pyruvate [ 11 , 24 , 46 ].…”
Section: Discussionmentioning
confidence: 99%
“…Unsaturated PHIP precursors were mixed with the Rh-based hydrogenation catalyst [54], and pH was then adjusted depending on the specific precursor under investigation ( e.g . by addition of HCl or phosphate buffer solutions [33, 67]). By holding valves v s1 , v s3 , v s5 closed, and actuating valves v s2 and v s6 (see Figure 1), the polarizer was flushed with N 2 (g) to clean and dry device fluid paths.…”
Section: Methodsmentioning
confidence: 99%
“…The experiments were performed on both in vitro acetate phantoms and rat torso in vivo data. The linewidths obtained at this field were compared with those at 4.7T and found an improvement by a factor of 12 at the lower field …”
Section: Current State Of the Artmentioning
confidence: 99%
“…The linewidths obtained at this field were compared with those at 4.7T and found an improvement by a factor of 12 at the lower field. 64 Low Field (LF) MRI (0.2-0.5T) The increase in magnetic field strength compared with ULF and VLF MRI provides for higher SNR, and a compromise on the economics of purchase, siting, and service. Also, the SNR gain typically expedites the path to clinical evaluation of e70…”
Section: Ulf Mri (<10 Mt)mentioning
confidence: 99%