2020
DOI: 10.3390/app10030819
|View full text |Cite
|
Sign up to set email alerts
|

High-Resolution Hologram Calculation Method Based on Light Field Image Rendering

Abstract: A fast calculation method for a full parallax high-resolution hologram is proposed based on elemental light field image (EI) rendering. A 3D object located near the holographic plane is firstly rendered as multiple EIs with a pinhole array. Each EI is interpolated and multiplied by a divergent sphere wave and interfered with a reference wave to form a hogel. Parallel acceleration is used to calculate the high-resolution hologram because the calculation of each hogel is independent. A high-resolution hologram w… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 24 publications
(33 reference statements)
0
9
0
Order By: Relevance
“…From this we can still see the similarities between the hologram structures. After the calculation of the entire hologram is completed, the hologram is combined and divided by the our software, and then exposed on the photoresist using a self-developed holographic printer [18], [19], and then developed by wet processing to form a high-resolution phase-only hologram for optical reconstruction. The relevant details of the holographic printer can be found in the link [26].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…From this we can still see the similarities between the hologram structures. After the calculation of the entire hologram is completed, the hologram is combined and divided by the our software, and then exposed on the photoresist using a self-developed holographic printer [18], [19], and then developed by wet processing to form a high-resolution phase-only hologram for optical reconstruction. The relevant details of the holographic printer can be found in the link [26].…”
Section: Resultsmentioning
confidence: 99%
“…Those methods are effective but not all suitable for highresolution hologram calculation due to the large amount of calculation. The fully computed holographic stereogram, frequency fusion method and light field image direct coding method have been proposed for high-resolution hologram calculation [17]- [19]. In reference [17], a high-resolution hologram with 20k×20k pixels was calculated with 32.9 hours.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Motivated by this limitation, we have proposed a new experimentally validated integral holographic 3D display without using FFT. The computation time is about 37 min for a high-resolution hologram at the resolution of 200 K × 200 K pixels [23]. However, only a grayscale holographic 3D display was achieved when using white light source as illumination [23].…”
Section: Introductionmentioning
confidence: 99%
“…The computation time is about 37 min for a high-resolution hologram at the resolution of 200 K × 200 K pixels [23]. However, only a grayscale holographic 3D display was achieved when using white light source as illumination [23].…”
Section: Introductionmentioning
confidence: 99%