2018
DOI: 10.1002/jms.4306
|View full text |Cite
|
Sign up to set email alerts
|

High‐resolution GC/MS studies of a light crude oil fraction

Abstract: The continuous development in analytical instrumentation has brought the newly developed Orbitrap‐based gas chromatography / mass spectrometry (GC/MS) instrument into the forefront for the analysis of complex mixtures such as crude oil. Traditional instrumentation usually requires a choice to be made between mass resolving power or an efficient chromatographic separation, which ideally enables the distinction of structural isomers that is not possible by mass spectrometry alone. Now, these features can be comb… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
29
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 38 publications
(31 citation statements)
references
References 40 publications
0
29
0
2
Order By: Relevance
“…Oleh karena itu, energi ionisas i (82)(83)(84)(85)(86) pertamanya cukup rendah yaitu pada 495,8 kj/mol. Sebaliknya, energi (87)(88)(89)(90)(91) ionisasi (92)(93)(94)(95)(96)(97)(98)(99)(100)(101) kedua sangat tinggi (4562 kj/mol), karna elektron pada kulit L lebih dekat ke ini atom. Akibatnya, natrium membentuk senyawa ionik (48) dengan bermuatan Na + .…”
Section: Pendahuluanunclassified
“…Oleh karena itu, energi ionisas i (82)(83)(84)(85)(86) pertamanya cukup rendah yaitu pada 495,8 kj/mol. Sebaliknya, energi (87)(88)(89)(90)(91) ionisasi (92)(93)(94)(95)(96)(97)(98)(99)(100)(101) kedua sangat tinggi (4562 kj/mol), karna elektron pada kulit L lebih dekat ke ini atom. Akibatnya, natrium membentuk senyawa ionik (48) dengan bermuatan Na + .…”
Section: Pendahuluanunclassified
“…Characterization of heavier crude oils is a challenging task since the amounts of volatile or semi‐volatile compounds are limited. Thus, the use of gas chromatography/mass spectrometry (GC/MS) is not a suitable method for the analysis of such complex samples or its heavier fractions . The above‐mentioned problem has been partially solved with the introduction of atmospheric pressure ionization sources .…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the use of gas chromatography/mass spectrometry (GC/MS) is not a suitable method for the analysis of such complex samples or its heavier fractions. 18,19 The above-mentioned problem has been partially solved with the introduction of atmospheric pressure ionization sources. 20,21 In this family, electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) are the most widely used ionization techniques in crude oil analysis.…”
mentioning
confidence: 99%
“…This technique has increasingly become the analytical tool of choice in numerous fields, such as proteomics, metabolomics, and environment . In recent research, the Orbitrap mass analyzer was also combined with an electron ionization (EI) ion source and used as a detector in one‐dimensional GC (GC–MS) . The advantage of EI is that the fragment patterns obtained are suitable for matching against the widely available National Institute of Standards and Technology (NIST) and Wiley MS spectra libraries, for rapid compound identification.…”
Section: Introductionmentioning
confidence: 99%
“…24 In recent research, the Orbitrap mass analyzer was also combined with an electron ionization (EI) ion source and used as a detector in one-dimensional GC (GC-MS). 25,26 The advantage of EI is that the fragment patterns obtained are suitable for matching against the widely available National Institute of Standards and Technology (NIST) and Wiley MS spectra libraries, for rapid compound identification. However, extensive fragmentation, lack of molecular ions, and high-mass fragment ions in EI 27 are factors limiting taking full advantage of its high mass accuracy.…”
Section: Introductionmentioning
confidence: 99%