High-Resolution Filtering for Improved Small Molecule Identification via GC/MS

Abstract: Gas chromatography-mass spectrometry (GC/MS) has long been considered one of the premiere analytical tools for small molecule analysis. Recently, a number of GC/MS systems equipped with high-resolution mass analyzers have been introduced. These systems provide analysts with a new dimension of information – accurate mass measurement to the third or fourth decimal place; however, existing data processing tools do not capitalize on this information. Beyond that, GC/MS spectral reference libraries, which have been… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
36
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 47 publications
(40 citation statements)
references
References 23 publications
0
36
0
1
Order By: Relevance
“…Metabolite intensity values were normalized to the total ion current (TIC) for the RAW files for each sample using previously described software 21 . Principal component analysis was conducted on log2-transformed TIC-normalized intensity values using the decomposition.PCA() method in Python's skickit learn module 24 .…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Metabolite intensity values were normalized to the total ion current (TIC) for the RAW files for each sample using previously described software 21 . Principal component analysis was conducted on log2-transformed TIC-normalized intensity values using the decomposition.PCA() method in Python's skickit learn module 24 .…”
Section: Discussionmentioning
confidence: 99%
“…Raw files were subsequently processed using in-house software 21 for deconvolution, peak alignment, quantitation, and identification. Cutoffs for peak quantitation were set to a minimum fragment count of 10, minimum observation of a given peak across all files set to 33%, and analyte/background signal set to 10.…”
Section: Sample Preparation and Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…However, the methods they developed for the GC-Orbitrap MS are not easily adaptable to other accurate mass GC-Time of Flight-MS (GC-TOF/MS) instruments. High Resolution Filtering (HRF) is another GC-Orbitrap based method, without 13 C labeling, that attempts to annotate every measured m/z peak in an EI mass spectrum, leveraging accurate mass to discern between possible identifications 14 .…”
Section: Introductionmentioning
confidence: 99%