2022
DOI: 10.1109/jphot.2022.3142072
|View full text |Cite
|
Sign up to set email alerts
|

High-Resolution Determination of Kinetic Parameters of Sucrose Hydrolysis Based on Weak Measurement

Abstract: We propose a high-resolution scheme for determining the kinetic parameters of sucrose hydrolysis based on the weak measurement, and the parameters including rate constant, half-life, activation energy and pre-exponential factor are experimentally determined. In the scheme, the postselection state of weak measurement is modified by the optical rotation angle in the process of sucrose hydrolysis, and the amplified spin-Hall shift acts as a probe for determining the kinetic parameters. The rate constant and half-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 42 publications
(38 reference statements)
0
2
0
Order By: Relevance
“…In recent decades, the SHEL has attracted wide attention and been extensively studied in * Author to whom any correspondence should be addressed. different physical systems, such as two-dimensional materials [5][6][7][8], Weyl semimetals [9,10], metasurfaces [11,12], surface plasma physics [13,14], and biosensing [15]. Specifically in these studies, SHEL was often used as an effective probe in precision metrology and biosensing since it was sensitive to material properties.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In recent decades, the SHEL has attracted wide attention and been extensively studied in * Author to whom any correspondence should be addressed. different physical systems, such as two-dimensional materials [5][6][7][8], Weyl semimetals [9,10], metasurfaces [11,12], surface plasma physics [13,14], and biosensing [15]. Specifically in these studies, SHEL was often used as an effective probe in precision metrology and biosensing since it was sensitive to material properties.…”
Section: Introductionmentioning
confidence: 99%
“…For example, Zhou et al successfully measured the layer numbers of graphene with the help of SHEL [5]. Tang et al utilized the SHEL to determine the chemical kinetic parameters [15]. However, the SHEL is usually very tiny, which hinders the study and application of the SHEL, thus finding approaches to enhance and directly observe SHEL is essential.…”
Section: Introductionmentioning
confidence: 99%