2008
DOI: 10.1002/anie.200800212
|View full text |Cite
|
Sign up to set email alerts
|

High‐Relaxivity MRI Contrast Agents: Where Coordination Chemistry Meets Medical Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
351
2

Year Published

2009
2009
2018
2018

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 420 publications
(362 citation statements)
references
References 100 publications
3
351
2
Order By: Relevance
“…Emission spectra were acquired on a HORIBA Jobin Yvon IBH FluoroLog-3 spectrofluorimeter, equipped with 3 slit double grating excitation and emission monochromators (2.1 nm/mm dispersion, 1200 grooves/mm). Spectra were reference corrected for both the excitation light source variation (lamp and grating) and the emission spectral 5 response (detector and grating). Luminescence lifetimes were determined on a HORIBA Jobin Yvon IBH FluoroLog-3 spectrofluorimeter, adapted for time-correlated single photon counting (TCSPC) and multichannel scaling (MCS) measurements.…”
Section: General Considerationsmentioning
confidence: 99%
See 3 more Smart Citations
“…Emission spectra were acquired on a HORIBA Jobin Yvon IBH FluoroLog-3 spectrofluorimeter, equipped with 3 slit double grating excitation and emission monochromators (2.1 nm/mm dispersion, 1200 grooves/mm). Spectra were reference corrected for both the excitation light source variation (lamp and grating) and the emission spectral 5 response (detector and grating). Luminescence lifetimes were determined on a HORIBA Jobin Yvon IBH FluoroLog-3 spectrofluorimeter, adapted for time-correlated single photon counting (TCSPC) and multichannel scaling (MCS) measurements.…”
Section: General Considerationsmentioning
confidence: 99%
“…Other techniques such as NMR or X-ray absorption spectroscopies may be used in the future to characterize and compare the coordination spheres of these metal complexes. The in vivo distribution patterns and biokinetics of the lanthanides have been investigated previously, 29,30 revealing an increase in bone 5 retention and a decrease in liver deposition along the lanthanide series. These patterns may be linked to an increase in lanthanide complex stability with the phosphate binding moieties of the bone matrices, similar to the stability increases observed with 3,4,3-LI(1,2-HOPO), as the metal ion becomes smaller and more acidic.…”
Section: Stability Increase Along the Lanthanide Seriesmentioning
confidence: 99%
See 2 more Smart Citations
“…[5] However, because of the disadvantages such as rapid clearance, poor cell uptake, non-specific binding and especially low relaxivity of these GBCAs, the development of higher relaxivity CAs is necessary. [6] According to Solomon-Bloembergen-Morgan (SBM) equation, the relaxivity of GBCAs is mainly determined by residence time (τ M ), the number of first-shell (inner) water molecules (q), rotational correlation time (τ R ), and electron spin relaxation time (T 1e ). For small molecular weight GBCAs, either increasing the parameter q or lengthening τ R could enhance the relaxivity.…”
Section: Introductionmentioning
confidence: 99%