2019
DOI: 10.1007/s10854-019-02627-9
|View full text |Cite
|
Sign up to set email alerts
|

High-rate LiNi0.815Co0.15Al0.035O2 cathode material prepared by spray drying method for Li-ion batteries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 38 publications
0
5
0
Order By: Relevance
“…Three main inflection areas are identified from the GITT curves of all samples. The biggest plateau around 3.7 V is consistent to the sharpest peak in the d Q /d V versus voltage (Figure a), indicating the H1 to M phase transformation . Upon the M to H2 transformations around 3.9 V, the diffusivity of B-NCA is the lowest, which may be an indication of the main structural collapsing is occurring at this stage for the sample.…”
Section: Resultsmentioning
confidence: 52%
See 1 more Smart Citation
“…Three main inflection areas are identified from the GITT curves of all samples. The biggest plateau around 3.7 V is consistent to the sharpest peak in the d Q /d V versus voltage (Figure a), indicating the H1 to M phase transformation . Upon the M to H2 transformations around 3.9 V, the diffusivity of B-NCA is the lowest, which may be an indication of the main structural collapsing is occurring at this stage for the sample.…”
Section: Resultsmentioning
confidence: 52%
“…The biggest plateau around 3.7 V is consistent to the sharpest peak in the dQ/dV versus voltage (Figure 8a), indicating the H1 to M phase transformation. 47 Upon the M to H2 transformations around 3.9 V, the diffusivity of B-NCA is the lowest, which may be an indication of the main structural collapsing is occurring at this stage for the sample. Similarly, third inflection around 4.15 V is the H2 to H3 transformation, possessing the higher Li + diffusivity for both of the CF-assisted NCA samples, indicating a higher preservation/recovery of the hexagonal layered structure.…”
Section: ■ Results and Discussionmentioning
confidence: 91%
“…All of the following cycles present three main peaks (3.74, 4.00, and 4.22 V) in the charge process, which are consistent with the d Q /d V profiles. Besides, the small peak belongs to a single-phase region of M. , Moreover, the CV curves at different scan rates of 0.05, 0.1, 0.15, 0.2, and 0.25 mV s –1 are also shown in Figure a–c. For the NCM-10 V samples, more obvious peaks can be observed than those of the NCM-5 V and NCM-15 V samples, indicating its better reaction kinetics in the charge/discharge process.…”
Section: Resultsmentioning
confidence: 87%
“…Due to the limitations of production technology and equipment standards, the solid content of commercial WPU dispersions is generally lower than 40%, and that of cationic WPU dispersions is even lower at around 30%. This has led to increased production and transportation costs, rising commodity prices, and limited its application in certain fields 6–9 . Therefore, the development of novel methods for producing WPU dispersions with high solid content has become a key research area in the industry.…”
Section: Introductionmentioning
confidence: 99%