High-quality endoscope reprocessing decreases endoscope contamination

Abstract: In the present study the contamination rate of endoscopes was low compared with results from other European countries, possibly due to the high quality of endoscope reprocessing, drying and storage.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 16 publications
0
11
1
Order By: Relevance
“…When the contamination definition for high-concern organisms by the Centers for Disease Control and Prevention was used, the contamination prevalence for DLEs was 8% in this study, similar to the interim results of the postmarket surveillance studies ordered by the U.S. Food and Drug Administration. 53 Recent studies assessing surveillance, 9,13,17,53 culture and quarantine strategies, 8,9,54,55 double high-level disinfection, 14,56 and ethylene oxide sterilization 11 have reported promising lower contamination rates, showing that reduction of contamination is feasible. In addition to the assessed interventions, the lower rates may also be the result of continuous feedback and raised alertness by the culture results for these studies, 9,14,55,56 or less-sensitive sampling and culture methods.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…When the contamination definition for high-concern organisms by the Centers for Disease Control and Prevention was used, the contamination prevalence for DLEs was 8% in this study, similar to the interim results of the postmarket surveillance studies ordered by the U.S. Food and Drug Administration. 53 Recent studies assessing surveillance, 9,13,17,53 culture and quarantine strategies, 8,9,54,55 double high-level disinfection, 14,56 and ethylene oxide sterilization 11 have reported promising lower contamination rates, showing that reduction of contamination is feasible. In addition to the assessed interventions, the lower rates may also be the result of continuous feedback and raised alertness by the culture results for these studies, 9,14,55,56 or less-sensitive sampling and culture methods.…”
Section: Discussionmentioning
confidence: 99%
“…Recent studies show that the incidence of duodenoscope contamination ranges from 0.3% to 30%. [8][9][10][11][12][13][14] The first nationwide PROCESS (Prevalence of contamination of complex endoscopes in the Netherlands) study showed that 15% of patient-ready duodenoscopes were contaminated with GI or oral microorganisms, that is, bacteria originating from previous patients. 15 Contamination of reprocessed duodenoscopes is attributed to their complex design, which includes a side viewing tip, forceps elevator, and elevator wire channel.…”
Section: Introductionmentioning
confidence: 99%
“…1,2 Studies show duodenoscope contamination incidences ranging from 1% to 35%. [9][10][11][12][13][14] A recent nationwide Dutch study by our group showed that 15% of the patient-ready duodenoscopes were contaminated with GI or oral flora, 15 indicating that patients undergoing ERCP have been exposed to contaminated equipment with risk of transmission.…”
mentioning
confidence: 99%
“…Some studies have revealed a significantly lower degree of GI endoscope contamination. For instance, in a study performed by Decristoforo et al in Austria, the microbial contamination rate of GI endoscopes was 1.3% to 4.6% according to the national guideline, suggesting the high quality of endoscope reprocessing, drying, and storage in this country ( 19 ). Possible reasons for the different contamination rates in these studies could be due to the different guidelines applied for precleaning, cleaning, disinfection, drying, and storage in endoscopy centers.…”
Section: Discussionmentioning
confidence: 99%