2015
DOI: 10.1016/j.nima.2015.06.010
|View full text |Cite
|
Sign up to set email alerts
|

High-precision three-dimensional field mapping of a high resolution magnetic spectrometer for hypernuclear spectroscopy at JLab

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…The experiment was performed at JLab Hall C using continuous wave electron beams accelerated by CEBAF. = 0.844 GeV/c) at the target were measured by the High resolution Kaon Spectrometer (HKS) [27,28] and High resolution Electron spectrometer (HES), respectively. The HKS, which has a Q-Q-D magnet configuration, was constructed and used in the previous (e, e ′ K + ) experiment, JLab E01-011 [13,14].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The experiment was performed at JLab Hall C using continuous wave electron beams accelerated by CEBAF. = 0.844 GeV/c) at the target were measured by the High resolution Kaon Spectrometer (HKS) [27,28] and High resolution Electron spectrometer (HES), respectively. The HKS, which has a Q-Q-D magnet configuration, was constructed and used in the previous (e, e ′ K + ) experiment, JLab E01-011 [13,14].…”
Section: Methodsmentioning
confidence: 99%
“…This reaction particle resolution results in sub-MeV energy resolution (FWHM) of hypernuclear energy levels. Refer to [14,27,28] for details of the magnets and particle detector systems.…”
Section: Methodsmentioning
confidence: 99%
“…Figure 3 shows a schematic of the experimental setup of JLab E05-115 in the experimental Hall C. The electron beam at E e = 2.344 GeV was incident on the production target which was installed at the entrance of the SPL. A K + and scattered electron via the (e, e ′ K + ) reaction were bent in opposite directions by the SPL and were measured with a high-resolution kaon spectrometer (HKS) [58,59] and a high-resolution electron spectrometer (HES), respectively. A "pre"-chicane beam line was designed and used instead of the existing beam line at JLab Hall C. A combination of the pre-chicane beam line and SPL allowed us to transport unused beams and Bremsstrahlung photons generated in the target toward beam and photon dumps, respectively, without any additional bending magnets between the target and dumps.…”
Section: B Magnetic Spectrometersmentioning
confidence: 99%
“…The experiment was designed to perform spectroscopy for A = 7, 12 and 28 hypernuclear systems. A new magnetic spectrometer (High Resolution Kaon Spectrometer, HKS [11]), which was designed to achieve a momentum resolution of ∆p/p ≃ 2 × 10 −4 FWHM, was constructed and introduced for a K + detection in JLab E01-011. The introduction of HKS allowed us to measure Λ hypernuclear structures with an energy resolution of about 0.7 MeV (FWHM).…”
Section: Experimental Setup and Analysismentioning
confidence: 99%