2012
DOI: 10.1364/ol.37.000202
|View full text |Cite
|
Sign up to set email alerts
|

High precision micro-displacement fiber sensor through a suspended-core Sagnac interferometer

Abstract: A sensing system for micro-displacement measurement based in a suspended-core fiber Sagnac interferometer is presented. The suspended-core fiber characterization was made through the use of an optical backscatter reflectometer, screening its multimodal and birefringent behavior. Its sensitivity to displacement measurements is shown to be due only to birefringence, being that core-cladding mode coupling is negligible. High precision (~0.45 μm) was obtained using three different measurement instruments, showing … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
38
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 84 publications
(40 citation statements)
references
References 9 publications
1
38
1
Order By: Relevance
“…In the particular case of the structure demonstrated in this work, the displacement sensitivity close to the critical coupling point exceeds 1 dB/µm. For comparison, this sensitivity value is more than two times the sensitivity achieved in [10] using the same bending plates in an interferometric structure. …”
Section: Methodsmentioning
confidence: 81%
See 1 more Smart Citation
“…In the particular case of the structure demonstrated in this work, the displacement sensitivity close to the critical coupling point exceeds 1 dB/µm. For comparison, this sensitivity value is more than two times the sensitivity achieved in [10] using the same bending plates in an interferometric structure. …”
Section: Methodsmentioning
confidence: 81%
“…We constructed the structure of Figure 3(a) with a fiber coupler, a polarization controller and a precision mechanic attenuator based on stress-inducing plates, similar to the one used in [10] (labeled BP in the Figure). The attenuation in the ring is varied by controlling the displacement of the plates through a precision actuator.…”
Section: Methodsmentioning
confidence: 99%
“…In the particular case of the structure demonstrated in this work, the displacement sensitivity close to the critical coupling point exceeds 1 dB/µm. For comparison, this sensitivity value is more than two times the sensitivity achieved in [11] using the same bending plates in an interferometric structure.…”
Section: Methodsmentioning
confidence: 81%
“…It has also been an important part of fiber filters and lasers [2]. Normally, the SLI is constructed by connecting the two output ends of a 3 dB coupler to form a closed-path loop.…”
Section: Introductionmentioning
confidence: 99%