High precision measurement of germanium isotope ratio variations by multiple collector-inductively coupled plasma mass spectrometry

Abstract: Multicollector ICP-MS is used for the precise measurement of variations in the isotopic composition of germanium. Argon-based spectral interferences are assessed in the germanium mass region and the repeatability of the following ratios is determined: 74 Ge/ 70 Ge, 73 Ge/ 70 Ge and 72 Ge/ 70 Ge. The isotope ratio repeatability of a mono-elemental solution relative to another mono-elemental solution is better than 0.06% per u at 95% confidence. Variations in sample 74 Ge/ 70 Ge, 73 Ge/ 70 Ge, and 72 Ge/ 70 Ge r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
53
0

Year Published

2003
2003
2014
2014

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(53 citation statements)
references
References 21 publications
0
53
0
Order By: Relevance
“…Instrumental mass bias within ICP-MS results from so-called 'space-charge' and 'ion-diffusion' effects on the transmission of ionized particles (Tanner, 1992;Vanhaecke et al, 1993;Maréchal et al, 1999) and has been shown to be sensitive to matrix composition (Galy et al, 2003;Pietruszka et al, 2006). In order to evaluate the possibility of matrix effects from elements that are commonly found in sulfide and sulfate minerals, we performed doping experiments using S spex standard solution mixed with various high-purity element solutions.…”
Section: Matrix Effectsmentioning
confidence: 99%
“…Instrumental mass bias within ICP-MS results from so-called 'space-charge' and 'ion-diffusion' effects on the transmission of ionized particles (Tanner, 1992;Vanhaecke et al, 1993;Maréchal et al, 1999) and has been shown to be sensitive to matrix composition (Galy et al, 2003;Pietruszka et al, 2006). In order to evaluate the possibility of matrix effects from elements that are commonly found in sulfide and sulfate minerals, we performed doping experiments using S spex standard solution mixed with various high-purity element solutions.…”
Section: Matrix Effectsmentioning
confidence: 99%
“…Stable isotope-ratio measurements using MC-ICP-MS have recently found a wider interest [206,[208][209][210][211]. While all isotopes can be used for stable isotope studies, subtle isotopic variations require an uncertainty of better than 0.1 ‰ using the R( 74 Ge/ 70 Ge) ratio; both isotopes have a relatively high abundance, and they exhibit the largest atomic mass difference.…”
Section: Germaniummentioning
confidence: 99%
“…Lead has four stable isotopes, 204 Pb, 206 Pb, 207 Pb, and 208 Pb, with isotopic abundances of 1.4, 24.1, 22.1, and 52.3 %, respectively, in naturally occurring terrestrial material. Only 204 Pb is primordial; the three heavier isotopes are radiogenic.…”
Section: Leadmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition to its high mass resolution and high sensitivity, its unique flat topped peaks produced in low resolution mode provide for a more accurate and precise isotope ratio measurement. [7][8][9][10][11] This has been reported to be better than 0.04% precision with a single detector and as low as 0.002% on instruments equipped with a multi-collector detector.…”
Section: Introductionmentioning
confidence: 99%