2004
DOI: 10.1140/epjd/e2003-00313-4
|View full text |Cite
|
Sign up to set email alerts
|

High precision description of the rovibronic structure of the I $\mathsf{_2}$ B-X spectrum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
42
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 77 publications
(42 citation statements)
references
References 34 publications
0
42
0
Order By: Relevance
“…The iodine B state is spectroscopically well known, and for ñ È 14 we find the values of T cl È 0.3 ps and T rev È 37 ps (28). Here T rev d T cl , which results from the weak anharmonicity in the excitation region.…”
mentioning
confidence: 62%
“…The iodine B state is spectroscopically well known, and for ñ È 14 we find the values of T cl È 0.3 ps and T rev È 37 ps (28). Here T rev d T cl , which results from the weak anharmonicity in the excitation region.…”
mentioning
confidence: 62%
“…Our original photon energy calibration was performed utilizing absorption lines energies of iodine from the atlas of Gerstenkorn and Luc [10]. Since our earlier work, re-examination of the iodine spectrum [6][7][8] has shown that a weakly energy-dependent systematic correction factor (≈−0.006 cm −1 at the probe laser frequencies in our spectral region) must be applied to the energies of Gerstenkorn and Luc. We derived additional corrections to the assumed energies of the observed iodine lines used for our calibration by convolving our experimental probe laser bandwidth with these improved values of the iodine lines to take account of blended lines and hyperfine structure.…”
Section: Limitations Of the Accuracy Of Our Previous Results For The Imentioning
confidence: 99%
“…Preferably, the series used should be free of perturbations, eliminating the need for a multichannel quantum defect theory treatment of the data. The evolution of laser spectroscopic techniques, along with improved values of atlases of calibration lines [6][7][8] (in this case the absorption lines of molecular iodine) has made new measurements possible, and also enabled the re-evaluation of older data to a higher degree of precision.…”
Section: Introductionmentioning
confidence: 99%
“…To this end, the dye laser output is directed to an existing setup for saturated absorption spectroscopy in an I 2 vapor cell [10]. As the I 2 spectrum has been well calibrated [11,12], it can also serve to independently determine the FSR of the FPI, and to assess the overall performance of our method.…”
Section: Frequency Calibrationmentioning
confidence: 99%