2008
DOI: 10.1364/oe.16.002486
|View full text |Cite
|
Sign up to set email alerts
|

High power 404 nm source based on second harmonic generation in PPKTP of a tapered external feedback diode laser

Abstract: Abstract:We present results on a 404 nm laser system based on second harmonic generation in a new compact external cavity configuration. We obtain a stable 318 mW cw diffraction limited output from the system with a mode-matched pump power of 630 mW. We observe up to 620 mW SHG, when the cavity is operating in scanning mode. The pump source is an external cavity grating feedback tapered diode laser operating at 808 nm. We find that thermal effects in the nonlinear crystal severely limit the efficiency of the s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
15
0

Year Published

2009
2009
2014
2014

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 30 publications
(18 citation statements)
references
References 21 publications
3
15
0
Order By: Relevance
“…1, is based on the same configuration that we reported in [6] with the pump source of similar design as reported in [7]. The laser output was 1.4 W measured before the isolator, and 1.2 W at the input of the external doubler resonator.…”
Section: Methodsmentioning
confidence: 99%
“…1, is based on the same configuration that we reported in [6] with the pump source of similar design as reported in [7]. The laser output was 1.4 W measured before the isolator, and 1.2 W at the input of the external doubler resonator.…”
Section: Methodsmentioning
confidence: 99%
“…A 318 mW, 404 nm frequency doubled diode laser was shown suitable for drug quantification measurements in a mouse model as part of photodynamic therapy [194,195]. The fluorescence initiated by the diode laser radiation helped to examine the drug uptake as well as its distribution, giving information about the location of tumors and its boundaries to healthy tissue.…”
Section: Biomedical Applications In the Visible Spectral Rangementioning
confidence: 99%
“…The SHG radiation will have only half the linewidth of the pump beam [29] and is hence well suited for isotope-selective photoionization. A drawback of using diode lasers for SHG is their elliptical beam shape [28], which reduces the conversion efficiency. To optimize the second harmonic power we therefore use an anamorphic prism pair (see Fig.…”
Section: Second Harmonic Generation At 423nm In Ppktpmentioning