2023
DOI: 10.1097/rli.0000000000000961
|View full text |Cite
|
Sign up to set email alerts
|

High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose

Abstract: ObjectivesThe aim of this study was to evaluate the high-helical pitch, multienergy (ME) scanning mode of a clinical dual-source photon-counting detector (PCD) computed tomography (CT) and the benefit of virtual monoenergetic images (VMIs) for low-contrast-dose coronary CT angiography (CTA).Materials and MethodsHigh-pitch (3.2) ME coronary CTA was performed in PCD-CT in 27 patients using low contrast dose (30 mL of iohexol 350 mg/mL) and in 26 patients at routine contrast dose (60 mL). Low-energy-threshold 120… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(7 citation statements)
references
References 35 publications
0
6
0
Order By: Relevance
“…Instead, they must be shown to have a positive impact on diagnostic accuracy and diagnostic confidence, and ideally to change the clinical management of patients. Initial studies already show an impact on diagnostic performance and diagnostic accuracy in various clinical fields, 46 , 68 , 77 , 86 , 87 and larger, more comprehensive clinical studies are sure to follow.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Instead, they must be shown to have a positive impact on diagnostic accuracy and diagnostic confidence, and ideally to change the clinical management of patients. Initial studies already show an impact on diagnostic performance and diagnostic accuracy in various clinical fields, 46 , 68 , 77 , 86 , 87 and larger, more comprehensive clinical studies are sure to follow.…”
Section: Discussionmentioning
confidence: 99%
“…The addition of 100 keV VMIs improved the diagnostic confidence in the evaluation of luminal stenosis associated with calcific plaques and stents and downgraded CAD-RADS scores in 9 patients by reducing blooming artifacts. 68 Virtual monoenergetic images are also used in CT scans without contrast agent, in which case special attention must be paid to the choice of keV level for quantitative applications such as Ca scoring. By choosing an appropriate combination of keV and strength of iterative reconstruction (Quantum Iterative Reconstruction QIR, Siemens Healthcare), Ca scoring results of EID-CT can be reproduced on PCD-CT.…”
Section: Spectral Imaging Capabilitiesmentioning
confidence: 99%
See 2 more Smart Citations
“…A recent advancement involves generating virtual monoenergetic images (VMIs) at higher keV levels (e.g., 100 keV) using photon counting detector (PCD) CT, which holds promise in reducing blooming artifacts and improving lumen visibility within cCTA images through its simultaneous high-resolution multi-energy imaging capability [2][3][4][5] . However, compared to PCD-CT, most EID-CT systems are limited to acquiring only single-energy CT (SECT) scans.…”
Section: Introductionmentioning
confidence: 99%