2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition 2009
DOI: 10.1109/apec.2009.4802877
|View full text |Cite
|
Sign up to set email alerts
|

High Performance Stationary Frame Filters for Symmetrical Sequences or Harmonics Separation Under a Variety of Grid Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(18 citation statements)
references
References 12 publications
0
18
0
Order By: Relevance
“…It should be note that the case of grid voltage and frequency deviations is out of scope of this paper. However, as stated in [19], the applied method is robust to small-frequency variations so that a high-performance output can be achieved even under a distorted grid voltage [14]. Although according to the allowable limits of frequency-deviation of main-grid [20], a phase-locked loop (PLL) can be avoided in the gridconnected mode [14], [19], for adapting to larger-frequency changes, a PLL or a frequency adaption loop can be added to the applied filter [19], [21].…”
Section: System Description and Modellingmentioning
confidence: 92%
See 1 more Smart Citation
“…It should be note that the case of grid voltage and frequency deviations is out of scope of this paper. However, as stated in [19], the applied method is robust to small-frequency variations so that a high-performance output can be achieved even under a distorted grid voltage [14]. Although according to the allowable limits of frequency-deviation of main-grid [20], a phase-locked loop (PLL) can be avoided in the gridconnected mode [14], [19], for adapting to larger-frequency changes, a PLL or a frequency adaption loop can be added to the applied filter [19], [21].…”
Section: System Description and Modellingmentioning
confidence: 92%
“…Since the whole controller is designed in the stationary reference frame, the sequence detection of system voltages and currents is also realized based on a stationary frame notch filter in the αβ-frame [19]. It should be note that the case of grid voltage and frequency deviations is out of scope of this paper.…”
Section: System Description and Modellingmentioning
confidence: 99%
“…Since the whole controller is designed in the stationary frame, the sequence detection of grid voltages is also realized based on a stationary frame filter cell in the αβ-frame [21]. As shown in Fig.…”
Section: A Control Realizationmentioning
confidence: 99%
“…Because of its robustness for small frequency variations, a phase locked loop (PLL) is avoided in the experiment since the ac power supply only emulates the magnitude drop of the grid voltage. Otherwise, a PLL should be added to the filter for adapting to large frequency changes [21]. Concerning the power factor angle ϕ, defined in (31), two values are tested in the experiment.…”
Section: A Control Realizationmentioning
confidence: 99%
“…Through optimizing, the parameters used in the experiment are K p =2, K r =100, and ω br =10 rad/s. Since the whole controller is designed in the stationary frame, the sequence detection of grid voltages is also realized based on a stationary frame filter cell in the α−β frame [15]. The basic filter cell can be easily implemented using a multistate-variable structure.…”
Section: A Control Realizationmentioning
confidence: 99%