2022
DOI: 10.3788/col202220.021201
|View full text |Cite
|
Sign up to set email alerts
|

High performance optical sensor based on double compound symmetric gratings

Abstract: A high performance optical sensor based on a double compound symmetric gratings (DCSGs) structure is designed. The reflection spectrum of the DCSG is investigated by utilizing a method that combines a theoretical model with the eigenmode information of the grating structure. The theoretical results, which are observed to agree well with those acquired by rigorous coupled-wave analysis, show that the linewidth of the reflection spectrum decreases upon the increasing distance between the grating strips. This res… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…All-dielectric structures that support BICs have been widely used in the design of high- Q biosensors based on their advantages of low loss and high functionality. In this section, some all-dielectric BICs biosensors are introduced, including BICs gratings [ 57 , 58 , 59 , 60 , 61 , 62 , 63 ], symmetry-broken [ 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 ] and topological-boundary-states-governed [ 78 ] BICs metasurfaces, and BICs PhCSs [ 56 , 79 , 80 , 81 , 82 , 83 , 84 , 85 , 86 ].…”
Section: Label-free Bics Optical Biosensors Based On Different Materi...mentioning
confidence: 99%
See 2 more Smart Citations
“…All-dielectric structures that support BICs have been widely used in the design of high- Q biosensors based on their advantages of low loss and high functionality. In this section, some all-dielectric BICs biosensors are introduced, including BICs gratings [ 57 , 58 , 59 , 60 , 61 , 62 , 63 ], symmetry-broken [ 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 , 77 ] and topological-boundary-states-governed [ 78 ] BICs metasurfaces, and BICs PhCSs [ 56 , 79 , 80 , 81 , 82 , 83 , 84 , 85 , 86 ].…”
Section: Label-free Bics Optical Biosensors Based On Different Materi...mentioning
confidence: 99%
“…Essentially, this setting can make the RI distribution of the grating layer non-uniform within a grating period, so a quasi-BIC with a high FOM can be obtained under specific asymmetric parameters. Based on the BICs-supported dual-grating metamembranes proposed by Hemmati et al [ 87 ], a double compound symmetric grating was designed by Shi et al [ 58 ], as shown in Figure 3 b. The resonant linewidth of quasi-BICs was tuned by changing the gap of the grating ridges, and a high FOM of 31,467 can be theoretically achieved.…”
Section: Label-free Bics Optical Biosensors Based On Different Materi...mentioning
confidence: 99%
See 1 more Smart Citation
“…Resonance sensors, known for their high sensitivity, label-free detection, miniaturization, and real-time monitoring capabilities, have been widely applied in ocean investigation [23], environmental monitoring [24,25], biomedicine [26], and liquid detection [27]. Lu et al proposed a one-dimensional GMR-based resonant grating sensor that uses a wavelength-tunable light source to track narrow resonant reflection peaks, achieving high sensitivity detection [28].…”
Section: Introductionmentioning
confidence: 99%