1999
DOI: 10.1016/s0378-4347(98)00587-8
|View full text |Cite
|
Sign up to set email alerts
|

High-performance liquid chromatography with peroxyoxalate chemiluminescence determination of propentofylline concentrations in rat brain microdialysate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2000
2000
2011
2011

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 8 publications
0
10
0
Order By: Relevance
“…DBD-H was used for the detemination of short-chain aliphatic aldehydes (Nakashima et al, 1994), 17-oxosteroids derivatives , 20-oxosteroids derivatives and their sulfates and choline glycerophospholipids (Ou et al, 1995). The derivatives with DBD-H were suitable for the peroxyoxalate chemiluminescence detection, and therefore DBD-H was used for the determination of medroxyprogesterone acetate , long chain aliphatic aldehydes (Nakashima et al, 1996) and propentofylline (Hamachi et al, 1999).…”
Section: For Carboxylic Acids Nbd-pzmentioning
confidence: 99%
“…DBD-H was used for the detemination of short-chain aliphatic aldehydes (Nakashima et al, 1994), 17-oxosteroids derivatives , 20-oxosteroids derivatives and their sulfates and choline glycerophospholipids (Ou et al, 1995). The derivatives with DBD-H were suitable for the peroxyoxalate chemiluminescence detection, and therefore DBD-H was used for the determination of medroxyprogesterone acetate , long chain aliphatic aldehydes (Nakashima et al, 1996) and propentofylline (Hamachi et al, 1999).…”
Section: For Carboxylic Acids Nbd-pzmentioning
confidence: 99%
“…The CL spectra produced from these reactions could be used for different analytical applications, based on the determination of fluorophores, peroxides , catalysts or quenchers used in the PO-CL system. Such multi-scope character of the PO-CL systems enables them to be employed as powerful analytical tools for the detection of a wide variety of analytes such as hydrogen peroxide [3,4], fluorescent compounds [5,6], catecholamines [7,8], carboxylic acids [9], carbonyl compounds [10], amines [11,12] and amino acids [13].…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, DBD moiety was found to be efficiently excited by PO-CL reaction. 13 Based on this fact, medroxyprogesterone acetate, 14 long-chain aliphatic aldehydes 15 and propentofylline 16 labeled with DBD-H could be sensitively determined by PO-CL detection. Figure 3 shows the chromatograms of DBD-hydrazones of 8 aliphatic aldehydes obtained by PO-CL detection with bis(2,4,6-trichlorophenyl)oxalate (TCPO) and hydrogen peroxide as CL reagents.…”
Section: ·1 Bezoxadiazole Derivatives 11-21mentioning
confidence: 99%