1982
DOI: 10.1016/s0378-4347(00)86037-5
|View full text |Cite
|
Sign up to set email alerts
|

High-performance liquid chromatographic determination of purine and pyrimidine bases, ribonucleosides, deoxyribonucleosides and cyclic ribonucleotides in biological fluids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

1983
1983
1995
1995

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(12 citation statements)
references
References 21 publications
0
12
0
Order By: Relevance
“…The blocker solution contained the adenosine deaminase inhibitor erythro-9(2-hydroxy-3-nonyl)-adenosine (10 uM), the adenosine transport inhibitor dipyridamole (20 OM) and the thrombocyte aggregation inhibitor indomethacine (2 mg/liter). Immediately after blood collection the blood/blocker mixture was centrifuged (model 3200; Eppendorf North America, Inc., Madison, WI) at 3,000 rpm for 2 min and the plasma was deproteinated with perchloric acid as described before (26). The extract was kept frozen at -20'C until the adenosine concentration was determined in duplicate by reversed-phase, high performance liquid chromatography using a nonlinear gradient.…”
Section: Methodsmentioning
confidence: 99%
“…The blocker solution contained the adenosine deaminase inhibitor erythro-9(2-hydroxy-3-nonyl)-adenosine (10 uM), the adenosine transport inhibitor dipyridamole (20 OM) and the thrombocyte aggregation inhibitor indomethacine (2 mg/liter). Immediately after blood collection the blood/blocker mixture was centrifuged (model 3200; Eppendorf North America, Inc., Madison, WI) at 3,000 rpm for 2 min and the plasma was deproteinated with perchloric acid as described before (26). The extract was kept frozen at -20'C until the adenosine concentration was determined in duplicate by reversed-phase, high performance liquid chromatography using a nonlinear gradient.…”
Section: Methodsmentioning
confidence: 99%
“…Purines and pyrimidines were determined by high-performance liquid chromatography according to a previously published method [7] and compared with normal values of purines and pyrimidines in CSF described before [8] and with control children for plasma. Heparinized plasma was centrifuged immediately after venipunc ture.…”
Section: Methodsmentioning
confidence: 99%
“…The re coveries of (methyl)thiopurine nucleosides and bases from plasma with PCA are good. The recovery of 6MP from plasma with trichloro acetic acid is even better (94%) [9].…”
Section: Resultsmentioning
confidence: 99%
“…Previously, v/e published HPLC methods for the detection of purine and pyrimidine nu cleotides [8], nucleosides and bases [9] and thiopurine nucleosides and bases [10,11], In the present article we describe two HPLC methods, one for measurement of methylthiopurine and thiopurine nucleosides and bases, and another for measurement of (methyl)thiopurine nu cleotides. Both methods are used in the clinical randomized ALL-8 trial of the Dutch Childhood Leukaemia Study Group.…”
Section: W Ken' En K Amp Jansen Ct At I J Ch Rom a Togr B 672mentioning
confidence: 99%