1994
DOI: 10.1016/0378-4347(94)00280-0
|View full text |Cite
|
Sign up to set email alerts
|

High-performance liquid chromatographic determination of hypotaurine and taurine after conversion to 4-dimethylaminoazobenzene-4′-sulfonyl derivatives and its application to the urine of cysteine-administered rats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
6
0

Year Published

1995
1995
2006
2006

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…Total sulfate (free plus ester) was determined by ion chromatography after hydrolysis as described . Taurine, and hypotaurine if any, was determined by reversed phase high-performance liquid chromatography after conversion to 4-dimethylaminoazobenzene-4'-sulfonyl-taurine (dabsyltaurine), and dabsyl-hypotaurine if any (Futani et al, 1994).…”
Section: Determination Of Glc-cys Cysteine Sulfate and Taurine In Umentioning
confidence: 99%
“…Total sulfate (free plus ester) was determined by ion chromatography after hydrolysis as described . Taurine, and hypotaurine if any, was determined by reversed phase high-performance liquid chromatography after conversion to 4-dimethylaminoazobenzene-4'-sulfonyl-taurine (dabsyltaurine), and dabsyl-hypotaurine if any (Futani et al, 1994).…”
Section: Determination Of Glc-cys Cysteine Sulfate and Taurine In Umentioning
confidence: 99%
“…The bulk of these are relatively involving pre-or interfere with the determination of taurine, purificapost-column derivatization followed by ultraviolet, tion procedures by a cation-exchange column fluorescence and / or electrochemical detection to 1 (Dowex 50W, 2.0 ml, 5.530.7 cm I.D., H form) improve both the quality of separation as well as [35] or an ion-exchange column filled with both an detection sensitivity. An obvious advantage of preanionic and cationic resin (Amberlite AG138, 200-column derivatization relatively to post-column de-400 mesh, 0.5 ml and Amberlite AG50W-38, 200-rivatization is that it requires a basic HPLC system 400 mesh, 1 ml) have been proved practical.…”
Section: Introductionmentioning
confidence: 99%
“…Futani et al conductivity detection. It cannot be detected with [35] found that dabsylhypotaurine once formed was UV detection due to the lack of an ultraviolet very stable, and it was not converted into chromophore. Zhu and co-workers [59,60] showed dabsyltaurine on storage at room temperature for that taurine, leucine and phenylalanine could be several months or on flash evaporation at 40 8C.…”
mentioning
confidence: 99%
See 2 more Smart Citations