1979
DOI: 10.1016/s0021-9673(00)95293-2
|View full text |Cite
|
Sign up to set email alerts
|

high-performance liquid chromatographic assay of vitamin k in human serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

1981
1981
2012
2012

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…Only cord blood samples provided enough material, but showed varying vita min Ki contents due to differences in analyt ical accuracies [7,29,31], including our ear lier results [27,29], using the method de scribed by Lefevere et al [22], Methods applying postcolumn reduction combined with fluorescence detection [22,25] seemed to cope with accuracy problems and with the limited amount of blood available from newborns. Applying the HPLC method described by Van Haard et al [10], we were able to measure vitamin Ki in small serum samples, and as we needed only 5 ml venous blood from neonates to investigate both vita min Ki and coagulation parameters, we could investigate each child several times in 4 weeks.…”
Section: Discussionmentioning
confidence: 76%
“…Only cord blood samples provided enough material, but showed varying vita min Ki contents due to differences in analyt ical accuracies [7,29,31], including our ear lier results [27,29], using the method de scribed by Lefevere et al [22], Methods applying postcolumn reduction combined with fluorescence detection [22,25] seemed to cope with accuracy problems and with the limited amount of blood available from newborns. Applying the HPLC method described by Van Haard et al [10], we were able to measure vitamin Ki in small serum samples, and as we needed only 5 ml venous blood from neonates to investigate both vita min Ki and coagulation parameters, we could investigate each child several times in 4 weeks.…”
Section: Discussionmentioning
confidence: 76%
“…Detection modes include ultraviolet [11], electrochemical [12], fluorescence [13], chemiluminescence [14] and mass spectrometry [15].…”
Section: Introductionmentioning
confidence: 99%
“…To determine normal levels of K1 in serum samples with a UV absorption detector, a sequential adsorption and reversed-phase HPLC procedure was developed (22). Obviously, this procedure lengthens the analysis time over a single chromatographic separation coupled to a more selective detector.…”
Section: Photoreduction/fluorescence Detection Of Quinones (Prfq)mentioning
confidence: 99%
“…Because vitamin K¡ (2-methyl-3-phytyl-l,4-naphthoquinone) is extremely hydrophobic, its determination after extraction from matrices that contain lipophilic interferents is quite challenging. To determine normal levels of Kx in serum samples with a UV absorption detector, a sequential adsorption and reversed-phase HPLC procedure was developed (22). Obviously, this procedure lengthens the analysis time over a single chromatographic separation coupled to a more selective detector.…”
Section: Introductionmentioning
confidence: 99%