1989
DOI: 10.1093/chromsci/27.2.86
|View full text |Cite
|
Sign up to set email alerts
|

High-Performance Liquid Chromatographic Analysis of Steroid Hormones

Abstract: In the present work, a practical, rapid, reliable and isocratic reversed-phase high-performance liquid chromatographic (HPLC) method is described for the qualitative and quantitative analysis of estriol, estradiol-17 beta, estrone, testosterone, and progesterone. Chromatographic separation is complete in 16 min using a mobile phase of 50% acetonitrile (v/v) in water. The order of elution is estriol, testosterone, estradiol-17 beta, estrone, and progesterone; retention times are 2.5, 5.5, 5.6, 6.9, 16.3 min, re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

1990
1990
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 0 publications
0
3
0
1
Order By: Relevance
“…HPLC analysis of testosterone was performed using Agilent 1290 infinity LC (Agilent Technology, Waldbronn, Germany). The analytical method was modified from Refs [ 40 ]. Samples were detected using an ultraviolet-visible (UV-Vis) spectroscopy detector, and the wavelength was set to 254 nm.…”
Section: Methodsmentioning
confidence: 99%
“…HPLC analysis of testosterone was performed using Agilent 1290 infinity LC (Agilent Technology, Waldbronn, Germany). The analytical method was modified from Refs [ 40 ]. Samples were detected using an ultraviolet-visible (UV-Vis) spectroscopy detector, and the wavelength was set to 254 nm.…”
Section: Methodsmentioning
confidence: 99%
“…[3H]El produced in two separate assays from diencephalic cultures was also tested with authentic radio-inert El (Steraloids) using high-performance liquid chromatography (HPLC) (Erkoc et al, 1989;Edmond et al, 1991). The radiolabeled steroid product and unlabeled steroid were dissolved in 50% acetonitrile and applied to the HPLC column [AXXI-CHROM C-18 (ODs); 5 pm particle size; RP-18 Newguard precolumn] at 34°C.…”
Section: Enzyme Assaysmentioning
confidence: 99%
“…After completion of incubation, the tissue samples were carefully rinsed and lyophilized. The tissue drug content was determined through extraction either by a F‐3010 Fluorescence spectrophotometer (Hitachi Ltd., Tokyo, Japan) for carboxyfluorescein (excitation 488 nm; emission 516 nm) and RH123 (excitation 498 nm; emission 525 nm) or by high performance liquid chromatography for testosterone10 and tacrolimus 11. Experiments in the presence of any inhibitor were performed similarly.…”
Section: Methodsmentioning
confidence: 99%