High-Intensity Airborne CMUT Transmitter Array With Beam Steering

Abstract: A 2 × 2 high-intensity CMUT transmit array that is capable of two-dimensional beam steering is presented. The device uses an ac drive voltage at half the ultrasound frequency without any dc bias, enabling the usage of the entire gap height. The device is designed using a large signal equivalent model approach. A fabrication method that requires a single lithographic mask has been used. The fabricated devices are operated at 76 kHz to beam steer at various angles. An equivalent element pressure of 144 dB//20 µP… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 48 publications
0
1
0
Order By: Relevance
“…To suppress grating lobes, non-uniform sparse array is proposed by breaking the periodicity of the element arrangement, which has been applied to beamforming in sound source localization [16], [17]. A more conservative approach is to meet the λ/2 criterion, which has been accomplished by developing tiny transducers based on PMUTS [18], CMUTS [19] or PVDF [20]. However, the tinier the transducer is, the higher cost it will take.…”
Section: Related Work a In-air Ultrasonic 3d Imagingmentioning
confidence: 99%
“…To suppress grating lobes, non-uniform sparse array is proposed by breaking the periodicity of the element arrangement, which has been applied to beamforming in sound source localization [16], [17]. A more conservative approach is to meet the λ/2 criterion, which has been accomplished by developing tiny transducers based on PMUTS [18], CMUTS [19] or PVDF [20]. However, the tinier the transducer is, the higher cost it will take.…”
Section: Related Work a In-air Ultrasonic 3d Imagingmentioning
confidence: 99%
“…The CMUT ultrasonic array, based on MEMS technology, has attracted great attention from researchers, industry and clinical institutions. This is because the CMUT ultrasonic array is smaller and more sensitive than traditional ultrasonic components [1][2][3][4][5]. The research findings of Stanford are the most prominent when it comes to CMUT devices [6][7][8][9].…”
Section: Introductionmentioning