2011
DOI: 10.1111/j.1552-6569.2011.00596.x
|View full text |Cite
|
Sign up to set email alerts
|

High b‐Value q‐Space Analyzed Diffusion‐Weighted MRI Using 1.5 Tesla Clinical Scanner; Determination of Displacement Parameters in the Brains of Normal versus Multiple Sclerosis and Low‐Grade Glioma Subjects

Abstract: We propose that the relative values of MD obtained by QSI in control and diseased tissues can be useful for diagnosing various WM abnormalities.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 23 publications
(35 reference statements)
0
4
0
Order By: Relevance
“…18,21 However, for q-space analysis, QSI-analyzer was introduced for calculating the FWHM of the PDF and the mean displacement of water molecules. 22,26,30,31 For diŠusional kurtosis analysis, diffusion kurtosis estimator (DKE) 29,32 and the combination of dTV¿FZR (http://www.ut-radiology. umin.jp/people/masutani/dTV.htm) and VOLUME-ONE software (http://www.volume-one.org/) have been introduced in the literature 33,34 (Fig.…”
Section: Software For Calculating Non-gaussian Metricsmentioning
confidence: 99%
“…18,21 However, for q-space analysis, QSI-analyzer was introduced for calculating the FWHM of the PDF and the mean displacement of water molecules. 22,26,30,31 For diŠusional kurtosis analysis, diffusion kurtosis estimator (DKE) 29,32 and the combination of dTV¿FZR (http://www.ut-radiology. umin.jp/people/masutani/dTV.htm) and VOLUME-ONE software (http://www.volume-one.org/) have been introduced in the literature 33,34 (Fig.…”
Section: Software For Calculating Non-gaussian Metricsmentioning
confidence: 99%
“…All QSI data were transferred to an independent PC, and MDP maps were obtained for each MPG axis by using software (QSI-analyzer; 25,27,28) applying the theory of q-space analysis (24,25). All conventional DWI images were transferred to an independent workstation, and ADC maps were obtained.…”
Section: Methodsmentioning
confidence: 99%
“…2 ). 15 , 16 In general, the advantage of QSI compared to DTI is its ability to detect pathologic conditions with higher sensitivity. 17 , 18 Moreover, QSI-based myelin imaging was introduced to monitor demyelination and remyelination in MS patients.…”
Section: Q-space Imagingmentioning
confidence: 99%