2017
DOI: 10.1063/1.4974574
|View full text |Cite
|
Sign up to set email alerts
|

High-frequency guided ultrasonic waves to monitor corrosion thickness loss

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 28 publications
0
5
0
Order By: Relevance
“…Similar to the procedure used in the static case, the values of ξ 0 and n in the dynamic case can be calculated by using an error minimising routine that best fits the FE data to the regression equation described in Eq. (15). Only the range of S values for ξ > 1 were considered for this analysis because of the limitation in FE accuracy as described above.…”
Section: B 3d Numerical Validationmentioning
confidence: 99%
See 1 more Smart Citation
“…Similar to the procedure used in the static case, the values of ξ 0 and n in the dynamic case can be calculated by using an error minimising routine that best fits the FE data to the regression equation described in Eq. (15). Only the range of S values for ξ > 1 were considered for this analysis because of the limitation in FE accuracy as described above.…”
Section: B 3d Numerical Validationmentioning
confidence: 99%
“…Potential drop [5], [6], phased array ultrasonics [7], [8], time of flight diffraction [9], [10] and Rayleigh surface waves [11], [12] are existing non-destructive testing (NDT) methods used to detect and size cracks, with these conventional techniques normally being employed at periodic plant shutdowns. Recently, structural health monitoring (SHM) is gaining more popularity as a replacement for traditional NDT methods because it can usually operate continuously during plant operation, avoids the cost of repeated access to difficult-to-access areas [13], [14] and has the ability to track the rate of damage progression [15]. However, the NDT techniques discussed above would not be practical in structural health monitoring over large volumes of welds because of the limited inspection coverage per transducer.…”
Section: Introduction and Related Workmentioning
confidence: 99%
“…It is pertinent to point out that fundamental lamb wave modes exist majorly at smaller product value of f–d. The antisymmetric modes have been revealed to be more sensitive to defects at a higher frequency than the symmetric mode in detecting microcracks [ 63 , 64 , 65 ]. It was revealed in the study done by Alleyne and Cawley in [ 64 ] that the sensitivity of the fundamental modes of the lamb waves are functions of damage depth, h to guided wave thickness, d ratio ( ).…”
Section: Ultrasonic Guided Wave Ugwmentioning
confidence: 99%
“…Apart from these, crevice, galvanic, fretting, groove, fatigue, edge and stress corrosion are also encountered in various loaded and dynamic loaded structures [ 124 , 125 , 126 ]. Fromme et al [ 127 ] studied the corrosion based thickness loss of marine steel plates, partly immersed in salt water. A partially noncontact method was used in which the Lamb waves (A 0 and S 0 ) were simultaneously excited using wedge transducer (at a center frequency of 450 KHz) and the reflected signal was collected with a laser interferometer.…”
Section: Research Literature Review On Various Aspects Of Ugws Tecmentioning
confidence: 99%