2000
DOI: 10.1016/s0167-577x(00)00039-2
|View full text |Cite
|
Sign up to set email alerts
|

High frequency dielectric behaviour of aluminium-substituted lithium ferrites

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
10
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(14 citation statements)
references
References 10 publications
3
10
0
Order By: Relevance
“…In addition dispersion of the values of tan d are observed at low frequencies; tan d then becomes frequency-independent above 20 kHz. [26][27][28] These results can be interpreted on the basis of the strong correlation between tan d and the type of conduction mechanism in the spinel ferrites. 8 The conduction mechanism is mainly depends on the hopping process in the octahedral B site, and a maximum loss peak is observed when the frequency of the external field is equal to the frequency of the hopping process.…”
Section: Dielectric Propertiesmentioning
confidence: 72%
“…In addition dispersion of the values of tan d are observed at low frequencies; tan d then becomes frequency-independent above 20 kHz. [26][27][28] These results can be interpreted on the basis of the strong correlation between tan d and the type of conduction mechanism in the spinel ferrites. 8 The conduction mechanism is mainly depends on the hopping process in the octahedral B site, and a maximum loss peak is observed when the frequency of the external field is equal to the frequency of the hopping process.…”
Section: Dielectric Propertiesmentioning
confidence: 72%
“…The electronic polarizations can orient themselves with the electric field at the lower frequency range but at higher frequency, the internal individual dipoles contributing to the dielectric constant can't move instantly. So as frequency of an applied voltage increases, the dipole response is limited and the dielectric constant diminishes [17,18,23]. Ordinary dielectric behavior shows for all fired sample and in case of 1,400°C samples a dielectric switching takes place at 33.5 kHz.…”
Section: Resultsmentioning
confidence: 90%
“…It can be seen also that tan ı versus frequency sometimes shows maxima. These maxima of tan ı as a function of frequency in ferrites are attributed to the coincidence of the hopping frequency of electrons with the frequency of the externally applied field [23][24][25]. The high values of losses may be very important in some future applications that depend mainly on the thermal effect of the losses.…”
Section: Resultsmentioning
confidence: 97%