2017
DOI: 10.1016/j.measurement.2017.03.036
|View full text |Cite
|
Sign up to set email alerts
|

High-frequency current sensor based on lead-free multiferroic BiFeO 3 -BaTiO 3 -based ceramics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 23 publications
0
6
0
Order By: Relevance
“…In particular, the 3-2 type polymer-based ME films exhibited proportional ME responses with a linear behavior under an applied H dc of ± 1000 Oe. To determine the sensing capability, the linearity of the ME films was calculated, and the r 2 values were 0.9992 (PVDF/CFO-i-LGO), 0.9978 (PVDF/CFO-i-MGO), and 0.9981 (PVDF/CFO-i-SGO), greater than those reported in the literature [ 43 ]. Therefore, the 3-2 type polymer-based ME films with reliable ME responses have a high feasibility and can be used in ME devices for biomedical-sensing applications.…”
Section: Resultsmentioning
confidence: 93%
“…In particular, the 3-2 type polymer-based ME films exhibited proportional ME responses with a linear behavior under an applied H dc of ± 1000 Oe. To determine the sensing capability, the linearity of the ME films was calculated, and the r 2 values were 0.9992 (PVDF/CFO-i-LGO), 0.9978 (PVDF/CFO-i-MGO), and 0.9981 (PVDF/CFO-i-SGO), greater than those reported in the literature [ 43 ]. Therefore, the 3-2 type polymer-based ME films with reliable ME responses have a high feasibility and can be used in ME devices for biomedical-sensing applications.…”
Section: Resultsmentioning
confidence: 93%
“…Among all these devices, ME compositebased current sensors have attracted considerable study interest because of their critical value in current monitoring and measurement. Through the efforts of researchers, the ME composite-based current sensors can be used to measure DC [10,11], power frequency (50 Hz in China) AC [12][13][14][15]. In DC and AC measurements, the ME current sensors are divided into open-loop [12][13][14][15] and closed-loop [16][17][18][19][20][21] structures.…”
Section: Introductionmentioning
confidence: 99%
“…(16) Shi et al proposed a high-frequency current sensor based on lead-free multiferroic BFO ceramic. (17) In this study, crystalline BFO thin films are obtained and their crystallinity and surface morphology are analyzed by X-ray diffraction (XRD) and scanning electron microscopy (SEM). Additionally, force response measurement is utilized to evaluate the piezoelectric properties of the thin films.…”
Section: Introductionmentioning
confidence: 99%