High Frame Rate Vector Flow Imaging: Development as a New Diagnostic Mode on a Clinical Scanner

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
35
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 17 publications
(36 citation statements)
references
References 17 publications
0
35
0
Order By: Relevance
“…Measurement of WSS value is another unique function of V flow imaging method. With the multidirectional transmissions and receptions methods, the true velocity vectors will be achieved without the correction of angle ( 24 ). WSS value analysis will be achieved by setting the measurement reference line parallel to the vessel wall and close to the vessel wall after obtaining dynamic blood flow.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Measurement of WSS value is another unique function of V flow imaging method. With the multidirectional transmissions and receptions methods, the true velocity vectors will be achieved without the correction of angle ( 24 ). WSS value analysis will be achieved by setting the measurement reference line parallel to the vessel wall and close to the vessel wall after obtaining dynamic blood flow.…”
Section: Discussionmentioning
confidence: 99%
“…WSS value analysis will be achieved by setting the measurement reference line parallel to the vessel wall and close to the vessel wall after obtaining dynamic blood flow. The WSS value calculated by V flow is convenient and accurate in evaluating carotid artery function ( 24 , 25 ). High WSS value was considered to be related with plaque instability ( 10 , 26 ).…”
Section: Discussionmentioning
confidence: 99%
“…On the PW Doppler spectrum, spurious spectral broadening can result from a large Doppler angle, a large sample volume (>3.5 mm), a sample volume located close to the vessel wall, or a high PW Doppler gain setting ( 32 ). V Flow uses multi-directional ultrasound transmission and reception ( 9 ) based on plane wave and focus wave interleaved scanning ( 11 ). The actual direction of the velocity is reconstructed by the velocity components from different directions.…”
Section: Discussionmentioning
confidence: 99%
“…sin θ i N: number of velocity measuring points in the ROI, θ i : flow velocity angle at ith measuring point, and Tur indices ranged from 0 to 1 (0-100%), 0 indicates pure laminar flow which means that all flow directions are exactly the same. The bigger the Tur is, the more turbulent the flow is (11).…”
Section: Flow Ultrasound Assessment Of Canine Femoral Arterymentioning
confidence: 99%
See 1 more Smart Citation